The purpose of this study is to explore manifestations of Heart Failure Using Infrared Thermal Imaging Technology.
Temperature is a vital and useful indicator for various diseases.Infrared thermal imaging (IRTI) allows the temperature representation of the body surface by thermal distribution, where it depends on the complex relationships defining the heat exchange processes between skin tissue, inner tissue, local vasculature, and metabolic activity. The decrease in cardiac output in heart failure activate a series of compensatory adaption that are intended to maintain cardiovascular homeostasis. One of most important adaptation is activation of sympathetic nervous system, which could cause peripheral cutaneous vasoconstriction and decrease the skim temperature. Hence, the skim temperature of heart failure would be lower than health people,but which could not discovery by eye. The investigators hypothesize that IRTI could evaluate heart failure by the imaging of temperature distribution in the face on early stages.The aim of this study is to determine the effectiveness of infrared thermal imaging in evaluating heart failure.
Study Type
OBSERVATIONAL
Enrollment
200
The IRS system is capable of precisely measuring and storing real-time thermal images with a resolution of 320×240 pixels (IRS S6md Shanghai,China). The camera has Focal Plane Array (FPA), Uncooled microbolometer detector, with a thermal sensitivity of 0.05 ℃ at 20℃ to 30℃. The thermal images were captured at a distance of one meter from the various body regions namely face and the images were analyzed by thermal software(version 1.0).
The 2nd Affiliated Hospital of Chongqing Medical University
Chongqing, Chongqing Municipality, China
RECRUITING3Rd People'S Hospital of Chengdu
Chengdu, Sichuan, China
NOT_YET_RECRUITINGThe First Affiliated Hospital of Sichuan Medical University:
Luzhou, Sichuan, China
Surface temperature (℃)of face and hand measured by Infrared (IR) camera
Time frame: up to 12 months
LVEF(left ventricular ejection fraction)
Time frame: up to 12 months
proBNP(pro Brain Natriuretic Peptide)
Time frame: up to 12 months
catecholamine levels
Time frame: up to 12 months
Entropy of thermal image
Entropy of thermal image: show chaos degree of skim temperature distribution.
Time frame: up to 12 months