Objective: The purpose of this study is to compare the efficacy and safety of ablation of Atrial Fibrillation (AF) drivers marked by spatiotemporal dispersions and Complex Fractionated Atrial Electrocardiograms (CFAEs) to Pulmonary Vein Isolation (PVI) based ablation in patients with persistent AF. Hypothesis: CFAE/spatiotemporal dispersion guided ablation will increase AF free survival compared to a PVI guided ablation. Patient population: Patients with persistent AF will be randomized based on a 2:1 ratio into one of two study arms: * CFAE/spatiotemporal dispersion guided ablation: CFAE mapping and ablation during AF aimed at restoring sinus rhythm during ablation. * PVI guided ablation: wide antral pulmonary vein isolation during mapping catheter control of pulmonary vein signals
Design: A prospective, multicenter, randomized unblinded clinical study. Objective: The purpose of this study is to compare the efficacy and safety of ablation of AF drivers marked by spatiotemporal dispersions and CFAEs guided ablation to PVI guided ablation in patients with persistent AF. Hypothesis: CFAE/spatiotemporal dispersion guided ablation will increase AF free survival compared to a PVI guided ablation. Enrollment: 180 patients will be enrolled in this study. Clinical Sites: International (including non EU-countries), multicenter study. Patient population: Patients with persistent AF (defined as atrial fibrillation which is sustained beyond 7 days but no more than one year, or lasting less than 7 days but necessitating pharmacologic or electrical cardioversion, but lasting longer than 48 hours) should be documented either on 12-lead ECG, transtelephonic monitoring (TTM), ambulatory holter monitoring (HM) or telemetry strip and a physician's note showing continuous AF. Furthermore patients who have failed at least one Anti Arrhythmic Drug (AAD) (Class I or III) as evidenced by recurrent symptomatic AF or intolerable side effects of the AAD. Eligible patients who sign the study informed consent form will be randomized based on a 2:1 ratio into one of two study arms: * CFAE/spatiotemporal guided ablation: CFAE/spatiotemporal dispersion mapping and ablation during AF aimed at restoring sinus rhythm during ablation. Pulmonal vein isolation will be checked before and after ablation using a mapping catheter * PVI guided ablation: wide antral pulmonary vein isolation during mapping catheter control of pulmonary vein signals Primary Endpoint: Freedom from recorded AF or atrial flutter or atrial tachycardia recurrences (\>30 seconds) without the use of AADs through 18 months follow-up, post-blanking, on either a 12 lead ECG on visits or on 24 hour holter monitoring or on symptom driven event monitoring. CFAE/spatiotemporal dispersions procedural details: To increase the accuracy of CFAE mapping, the Pentaray mapping catheter will be used to define spatiotemporal dispersion areas of CFAEs as specific targets of ablation as described by Seitz (see also citation) as follows. Dispersion areas are defined as clusters of electrograms, either fractionated or non-fractionated, that display interelectrode time and space dispersion at a minimum of 3 adjacent bipoles such that activation spread over all the AFCL. At each bipole in a dispersion area, one or more of the following fractionated or nonfractionated electrogram morphologies can be found: 1. continuous, low-voltage fractionated electrograms ("continuously fractionated signal"); 2. bursts of fractionated electrograms ("trains of fractionation"); 3. fast nonfractionated electrograms (AFCL \<120 ms; "rapid fires"); and 4. slow nonfractionated electrograms (AFCL \>120 ms). Multipolar electrogram dispersion and non-dispersion regions, illustrate that fractionated electrograms are found in both dispersion and non-dispersion regions. CFAE software can be used, but CFAE ablation is not guided by the software, but based on visual judgement. Preferably a CFAE map will be made before ablation to judge the sites of most extensive CFAE sites. Baseline mapping in both atria will be performed during AF with the PentaRay multispline catheter sequentially positioned in various regions of the RA and LA. At each location, the catheter will be maintained in a stable position for a minimum of 2.5 s. The operator will look for dispersion areas (electrograms exhibiting both time and spatial dispersion). Where dispersion are found and/or the catheter is not stable for 2.5 s, acquisitions will be repeated. Additional risks: No additional risks are anticipated for patients enrolled in this study compared to patients undergoing ablation of symptomatic AF outside of the study, because the same catheter is used as in patients outside the study, and both methods (PVI and CFAE) are part of daily practice. Although none reported in the literature so far, CFAE ablation may cause more extensive lesions than other ablation for persistent atrial fibrillation, especially in the posterior wall. This in turn may cause pericardial effusion, myocardial rupture and atrio-esophageal fistula. All of these are potentially life threatening. However, energy settings are changed according to myocardial wall size and pressure recordings, in order to prevent these complications. Furthermore, also in the group of wide antral ablation, the posterior wall is targeted, possibly resulting in the same events. For prevention of posterior wall injury, temperature monitoring in the oesofagus may be used. Thrombus formation is a complication that can occur with any ablation technique. Thrombi may dislodge and embolize, causing a stroke, myocardial infarction or other ischemic event. Therefore, it is required that activated clotting time (ACT) is kept above 300 seconds. This should be monitored every 30 minutes, and heparin should be administered depending on the outcome. The operator is responsible for maintaining an adequate ACT. Radiation exposure during the fluoroscopic imaging of the catheters may result in an increase in the lifetime risk of developing a fatal malignancy (0.1%) or a genetic defect in offspring (0.002%). Potential Benefit: The direct benefit for patients undergoing ablation is the potential elimination of AF episodes. It is furthermore expected that quality of life will improve and less frequent hospitalization will be needed. Whether further morbidity as cerebral vascular events are prevented is subject to discussion. The information gained from the conduct of this study may benefit patients with AF by improving future treatment modalities.
Study Type
INTERVENTIONAL
Allocation
RANDOMIZED
Purpose
TREATMENT
Masking
NONE
Enrollment
180
CFAE/spatiotemporal dispersions mapping and ablation during AF aimed at restoring sinus rhythm during ablation. Pulmonal vein isolation will be checked before and after ablation using a mapping catheter.
Wide antral pulmonary vein isolation during mapping catheter control of pulmonary vein signals
Hopital Saint Joseph
Marseille, France
RECRUITINGCHU de Nice
Nice, France
NOT_YET_RECRUITINGKagoshima University
Kagoshima, Japan
RECRUITINGIsala
Zwolle, Overijssel, Netherlands
RECRUITINGFreedom from recorded atrial fibrillation or atrial flutter or atrial tachycardia (>30 seconds) recurrences without the use of class I or III AADs
Freedom from recorded atrial fibrillation or atrial flutter or atrial tachycardia recurrences (\>30 seconds) without the use of class I or III AADs through 18 months follow-up, post blanking period after ablation on either a 12 lead ECG on visits or on 24 hour holter monitoring or on symptom-driven event monitoring
Time frame: 18 months
Freedom from recorded atrial fibrillation or atrial flutter or atrial tachycardia recurrences (>30 seconds) regardless of antiarrhythmic drugs
Freedom from recorded atrial fibrillation or atrial flutter or atrial tachycardia recurrences (\>30 seconds) through 18 months follow-up on either a 12 lead ECG on visits or on 24 hour holter monitoring or on symptom-driven event monitoring, regardless of antiarrhythmic drugs
Time frame: 18 months
Freedom from recorded atrial fibrillation or atrial flutter recurrences (>30 seconds) regardless of antiarrhythmic drugs
Freedom from recorded atrial fibrillation or atrial flutter recurrences (\>30 seconds) through 18 months follow-up on either a 12 lead ECG on visits or on 24 hour holter monitoring or on symptom-driven event monitoring, regardless of antiarrhythmic drugs
Time frame: 18 months
Freedom from recorded atrial fibrillation or atrial flutter or atrial tachycardia recurrences (>30 seconds), without a new AAD or a previously failed AAD at a greater than the highest ineffective historical dose
Freedom from recorded atrial fibrillation or atrial flutter or atrial tachycardia recurrences (\>30 seconds) through 18 months follow-up on either a 12 lead ECG on visits or on 24 hour holter monitoring or on symptom-driven event monitoring, without a new AAD or a previously failed AAD at a greater than the highest ineffective historical dose
Time frame: 18 months
Freedom from recorded atrial fibrillation (>30 seconds), regardless of antiarrhythmic drugs
Freedom from recorded atrial fibrillation (\>30 seconds) through 18 months follow-up on either a 12 lead ECG on visits or on 24 hour holter monitoring or on symptom-driven event monitoring, regardless of antiarrhythmic drugs
Time frame: 18 months
Clinical/partial success at 18 months regardless of antiarrhythmic drug use
Clinical/partial success at 18 months regardless of antiarrhythmic drug use, defined as a 75% or greater reduction in the number of AF episodes and/or the duration of AF episodes, or the % time a patient is in AF as assessed with a device capable of measuring AF burden
Time frame: 18 months
Time to first symptomatic, recorded AF recurrence
Time to first symptomatic, recorded AF recurrence
Time frame: 18 months
Time to first electrocardioversion
Time to first electrocardioversion
Time frame: 18 months
Symptoms associated with atrial arrhythmias
Symptoms associated with atrial arrhythmias. Measured by CCS-SAF scale (Canadian Cardiovascular Society Severity of Atrial Fibrillation Scale)
Time frame: 18 months
Decreased anti-arrhythmic and/or anticoagulant drug use.
Decreased anti-arrhythmic and/or anticoagulant drug use will be recorded by checking the patients medication chart
Time frame: 18 months
Quality of life at 6 and 12 months compared to baseline
Quality of life at 6 and 12 months compared to baseline. Measured by SF36-version 2
Time frame: 6 months and 12 months
Number of redo-procedures
Number of redo-procedures
Time frame: 18 months
Total time of fluoroscopy
Total time of fluoroscopy
Time frame: 1 day
Total procedure time
Total procedure time (minutes from introduction of first catheter to withdrawal of last catheter)
Time frame: 1 day
Total ablation time
Total ablation time
Time frame: 1 day
Clinical adverse events
Clinical adverse events (TIA,CVA, hemorrhage, tamponade, myocardial infarction, symptomatic pulmonary vein stenosis (\> 50%), or other complications associated with AF ablation as listed in and defined by the table 6 of the 2012 HRS/EHRA/ECAS Expert Consensus Statement on Catheter and Surgical Ablation2)
Time frame: 18 months
The combined endpoint consisting of: Mortality and Hospitalization
The combined endpoint consisting of: Mortality and Hospitalization
Time frame: 18 months
This platform is for informational purposes only and does not constitute medical advice. Always consult a qualified healthcare professional.