Four methods of preoxygenation will be compared in healthy volunteers
After informed consent, each volunteer will undergo the following techniques: Simple mask at "flush" flow (40-60 L/min) Non-rebreather mask at 15 L/min Non-rebreather mask at 60 L/min Bag valve mask with one way exhalation valve at 15 L/min After 3 minutes, the exhaled oxygen will be measured with an oxygen sensor
Study Type
INTERVENTIONAL
Allocation
NON_RANDOMIZED
Purpose
TREATMENT
Masking
NONE
Enrollment
26
After 3 minutes of oxygen supplementation (preoxygenation), with each of the devices listed below, the exhaled oxygen content will be measured. All participants were enrolled in a single arm in which they underwent 4 interventions in series: 1) Simple mask at 60 L/min for 3 minutes 2) Non-rebreather at 60 L/min for 3 min 3) Non-rebreather at 15 L/min for 3 minutes 4) Bag valve mask at 15 L/min for 3 minutes
Exhaled Oxygen Concentration
Subjects will blow into an oxygen sensor after each method (arm). The primary outcome will be a non-inferiority test between bag valve mask and non-rebreather at 60 L/min. The remaining tests will be completed for comparison, but not part of formal statistical testing.
Time frame: Immediately after 3 minutes of oxygen supplementation