This study is aimed at presbyopic patients that do not require magnifying glass at close rage. The purpose of this study is to investigate the functional and physiological changes in eye induced by pinhole glass.
Study Type
INTERVENTIONAL
Allocation
NA
Purpose
BASIC_SCIENCE
Masking
NONE
Enrollment
40
Chung-Ang University Hospital
Seoul, South Korea
RECRUITINGDistant visual acuity (logMAR)
Distant visual acuity were measured using Snellen chart (Precision Vision, La Salle, IL, USA) at 4 m.
Time frame: Subjects performed this examination while wearing multiple pinhole and without wearing pinhole with one week apart in random order after baseline study
BUT
fluorescein is instilled into the subject's tear film and the subject is asked not to blink while the tear film is observed under a broad beam of cobalt blue illumination
Time frame: Subjects performed this examination while wearing multiple pinhole and without wearing pinhole with one week apart in random order after baseline study
Near point of accommodation (NPA)
Near point of accommodation (NPA) was measured using Donder's push-up method.
Time frame: Subjects performed this examination while wearing multiple pinhole and without wearing pinhole with one week apart in random order after baseline study
The fusional convergence
With the subject watching the 20/30 sized fixation target at 40 cm, we take the base-out bar prism on the subject's right eye. While gradually increasing the extent of the prism, the first point that the subject noticed diplopia was defined as the break point.
Time frame: Subjects performed this examination while wearing multiple pinhole and without wearing pinhole with one week apart in random order after baseline study
Stereopsis
Stereopsis was checked with the Randot Stereotest (Stereo Optical Co., Chicago, IL, USA).
Time frame: Subjects performed this examination while wearing multiple pinhole and without wearing pinhole with one week apart in random order after baseline study
Reading speed (letters per second)
Reading speed was evaluated using the famous Korean traditional fairy tale book. This Korean book was printed black-and-white with 10-font size.
This platform is for informational purposes only and does not constitute medical advice. Always consult a qualified healthcare professional.
Time frame: Subjects performed this examination while wearing multiple pinhole and without wearing pinhole with one week apart in random order after baseline study
Photopic pupil size (baseline, mm)
Pupil size under photopic conditions (85 cd/m2) was measured using a WASCA Analyzer (Carl Zeiss Meditec, Oberkochen, Germany).
Time frame: Subjects performed this examination while wearing multiple pinhole and without wearing pinhole with one week apart in random order after baseline study
Pupil size with the one eye pinhole glasses (mm)
Pupil size with the one eye pinhole glasses was measured using a WASCA Analyzer (Carl Zeiss Meditec, Oberkochen, Germany).
Time frame: Subjects performed this examination while wearing multiple pinhole and without wearing pinhole with one week apart in random order after baseline study