To investigate whether addition of the Biobridge scaffold to the standard surgery for vascularized lymph node transfer will improve the outcome of surgical treatment in lymphedema of the upper arm.
The investigators will perform lymph scans (lymphoscintigrams) before surgery and one year following surgery to determine the success of the surgery. In addition, the volume of the operated arm will be monitored by repeated measurement with a tape measure. The investigators will also track bioimpedance, a painless technique to detect fluid in the tissues. The investigators will obtain small skin biopsies and blood samples to detect the biological changes that may occur as a result of successful surgery.
Study Type
INTERVENTIONAL
Allocation
NA
Purpose
TREATMENT
Masking
NONE
Enrollment
1
Biobridge is surgically implanted with conventional vascularized lymph node transfer surgery
Stanford University
Stanford, California, United States
Change in Limb Volume
Lymphoscintigraphy, a measure of limb volume indicative of adequate limb drainage, was conducted on the arm receiving BioBridge implantation (affected arm) and the contralateral (unaffected) arm, before surgery (baseline) and 1 year following surgical implantation of the Biobridge device. The outcome is reported as the median difference in the pre-implantation baseline value and the value 1 year after surgery for each arm.
Time frame: 1 year
Serial Lymphoscintigraphy (LSG)
Lymphoscintigraphy, a measure of limb volume for which changes are indicative of adequate limb drainage, was conducted on the arm receiving the BioBridge implantation (baseline) and 1 year following the Biobridge implantation. The outcome is reported as the median difference in measured volume for affected arm from baseline to 1 year.
Time frame: 1 year
Bioimpedance Spectroscopy
Bioimpedance spectroscopy (BIS) is a non-invasive technique to measure the volume of fluid in various parts of the body, and can be used to assess the extent of lymphedema. BIS involves passing an extremely low-strength electrical current through the area and measuring how the flow of the current is slowed by the fluid in the body, and is reported as Ri in ohms, meaning the resistance of the intracellular fluid. BIS was conducted on the arm with the BioBridge implant, at baseline and 1 year after surgery. The outcome is reported as the median difference between baseline and 1 year after surgery in the arm receiving the BioBridge implant.
Time frame: 1 year
Caliper Skin-fold Thickness
Skin fold thickness as measured by calipers was used as a measure of fluid retention. Skin fold thickness was measured at the upper arm, forearm, and back of the hand, at baseline and at 1 year following surgical implantation of the Biobridge device. An increase in skin thickness means increased fluid retention. The outcome is reported as the median difference of skin fold thickness in millimeters (mm) for each location on the arm receiving the BioBridge implant, from baseline to 1 year.
This platform is for informational purposes only and does not constitute medical advice. Always consult a qualified healthcare professional.
Time frame: 1 year
Cutaneous Punch Biopsy of Skin
Serial changes in histopathology will be determined via a blinded assessment of serial cutaneous punch biopsies specimens.
Time frame: 1 year
Quality of Life for Limb Lymphoedema (LYMQOL)
Quality-of-life was assessed using the LYMQOL survey, a 5-question survey for improved function, appearance, symptoms, mood, and overall QOL. Overall QoL was reported on a 10-point scale with 10 being best, and the other assessments were for disease impact on a 4-point response scale consisting of 1 (none), 2 (a little), 3 (quite a bit), 4 (a lot), with lower values representing minimal disease (lymphedema) impact on the parameter and higher values representing a greater negative effect on the parameter. The outcome is reported as the median.
Time frame: 1 year