This is a pilot study of patients undergoing structural heart disease procedures that utilize TEE and fluoroscopic guidance at the New York University (NYU) Langone Medical Center. Patients in this study will undergo their procedure utilizing the TEE/Angio fusion software prototype. This protocol is primarily intended to ascertain the potential utility of the software prototype in the study population and to provide data and feedback to improve the workflow and algorithms of the prototype. As such, a primary outcome variable and statistical analysis plan have not been identified. However, procedural time, measures of radiation exposure (dose area product, total radiation dose, fluoroscopy time), degree of residual valvular regurgitation or paravalvular regurgitation as applicable, and complications will be recorded.
This study is for patients planned to undergo a transcatheter-based structural heart disease procedure that utilizes TEE and fluoroscopic guidance at the NYU Langone Medical Center. It will evaluate the utility and workflow of the transesophageal echocardiography/angiography (TEE/Angio) fusion software prototype to provide visualization of anatomic landmarks and guidance during structural heart disease procedures. The purpose of this study is to evaluate software (TEE/Angio fusion) that merges images from two standard procedures (ultrasound and x-ray) used to look at the heart during a procedure for structural heart disease. Typically, these 2-dimensional images are viewed separately, requiring the operator to mentally merge the two images together while deciding if he/she is in the correct location for the treatment strategy. TEE/Angio fusion is designed to make a single 3-dimensional image of the heart in real-time.
Study Type
OBSERVATIONAL
Enrollment
20
The TEE probe will be inserted into the patient's esophagus, after anesthetic induction or conscious sedation is administered, and removed after the completion of the procedure. Once the TEE probe is placed, the interventional cardiologist will acquire 2 fluoroscopic images with the TEE probe. These images will be used to co-register the ultrasound and fluoroscopy systems. As part of routine care, TEE and fluoroscopy images will be acquired throughout the procedure for clinical purposes. As new fluoroscopy images are acquired, the prototype software will automatically track the location of the TEE probe. When the echocardiographer has an image of a cardiac structure of interest, he may use the prototype software to place landmarks. The echocardiographer may then press a button to have the landmarks displayed on the fluoroscopy image that is only visible on an assist monitor and will not interfere with the standard fluoroscopy imaging monitor.
New York University Langone Medical Center
New York, New York, United States
Procedural Time'
Time frame: One day
Dose Area Product of Radiation Exposure
Once the TEE probe is placed, the interventional cardiologist will acquire 2 fluoroscopic images with the 'tee probe in view, at least 30 degrees apart. These 2 images will be used to co-register the ultrasound and fluoroscopy systems. The document entitled, "NSR\_EchoXrayFusion", this adds a negligible amount of radiation exposure (0.0006%).
Time frame: One day
Degree of residual valvular or paravalvular regurgitation
Time frame: One day
Total Radiation Dose
Time frame: One Day
Fluoroscopy Time
Time frame: One Day