Fighting against the pain caused by the disease or by the diagnostic and therapeutic procedures for children is a daily and essential concern of health care in the pediatric sector. The quantification of pain is needed to effectively adjust analgesic therapy while limiting the side effects of treatment. Nowadays many scales are validated for children, but they are based on one-off measures and hetero assessments are often subjective and dependent on many factors including the presence of staff to children's sides. Recent developments in the analysis of the cardiac signal in real time under the influence of autonomic control, have led to the development of a new painful stress quantification index. A monitor has recently been developed and provides an index of nociception and analgesia (ANI index). The validation of this nociception index has not been validated for pediatric care in a sector where particular attention is given to control pain. The main purpose of this study is to show the consistency of the index compared to a validated pain scale and used routinely in non-sedated children hospitalized in pediatric intensive care units. The caregiver will have the opportunity to fine tune the effective treatment.
Fighting against the pain caused by the disease or by the diagnostic and therapeutic procedures for children is a daily and essential concern of health care in the pediatric sector. The quantification of pain is needed to effectively adjust analgesic therapy while limiting the side effects of treatment. Nowadays many scales are validated for children, but they are based on one-off measures and hetero assessments are often subjective and dependent on many factors including the presence of staff to children's sides. Recent developments in the analysis of the cardiac signal in real time under the influence of autonomic control, have led to the development of a new painful stress quantification index. A monitor has recently been developed and provides an index of nociception and analgesia (ANI index). It is based on the study of the variability of the heart rate control changes in sympathetic and parasympathetic systems in response to stimuli. Clinical correlations have been completed for most of adult patients during or after general anesthesia. The validation of this nociception index has not been validated for pediatric care in a sector where particular attention is given to control pain. The main purpose of this study is to show the consistency of the index compared to a validated pain scale and used routinely in non-sedated children hospitalized in pediatric intensive care units. This study is based on a real-time analysis of the perception of pain in children. It is a critical validation step that could dramatically change the treatment of pediatric patients in intensive care and pediatric intensive care units by facilitating real-time patient management. The caregiver will have the opportunity to fine tune the effective treatment. The validation of this stool will allow the pain measure for children highly sedated or presenting a neuromotor handicap.
Study Type
OBSERVATIONAL
Enrollment
30
Each file consists of a simultaneous recording of an ECG signal, according to usual practice, coupled with a record of ANI Index (Analgesia Nociception Index) by MetroDoloris®. The ECG signals and the ANI index are recorded simultaneously on a computer.
Chu Saint-Etienne
Saint-Etienne, France
ANI Index
ANI Index will be measured during 24 hours and coated from 0 to 100 to have an idea of the patient's pain. It will also be compared to the FLACC Score (Face-Legs-Activity-Cry-Consolability Score) that is routinely measured and coated from 0 to 10.
Time frame: 24 hours
HFnu Index
High Standard Frequency Index (HFnu) of Short Term RR variability in heart rate (HRV) in the frequency domain will be measured at 24 hours.
Time frame: 24 hours
Ptot
Ptot is a cardiac frequency variability index and it will be measured at 24 hours.
Time frame: 24 hours
VLF
VLF (Very Low Frequencies) is a cardiac frequency variability index and it will be measured at 24 hours.
Time frame: 24 hours
LF
LF (Low frequencies) is a cardiac frequency variability index and it will be measured at 24 hours.
Time frame: 24 hours
HF
HF (High Frequencies) is a cardiac frequency variability index and it will be measured at 24 hours.
Time frame: 24 hours
LF/HF Ratio
LF (Low Frequencies) / HF (High Frequencies) Ratio is a cardiac frequency variability index and it will be measured at 24 hours.
Time frame: 24 hours
SDNN
SDNN (Standard Deviation of all NN intervals) is a cardiac frequency variability index and it will be measured at 24 hours.
Time frame: 24 hours
SDANN
SDANN (Standard Deviation of the Averages of NN intervals) is a cardiac frequency variability index and it will be measured at 24 hours.
Time frame: 24 hours
pNN50
pNN50 (NN50 count divided by the total number of all NN intervals) is a cardiac frequency variability index and it will be measured at 24 hours.
Time frame: 24 hours
This platform is for informational purposes only and does not constitute medical advice. Always consult a qualified healthcare professional.