Current EIT analyses are based on the assumption of a circular thorax-shape and do not provide any information on lung borders. The aim is to obtain the body and lung border contours of male subjects by multi-detector computed tomography (MDCT) in defined thresholds of anthropometric data (gender = male; height; weight) for calibration of more realistic EIT reconstruction models.
A major drawback of EIT is its relatively poor spatial resolution and its limitation in measuring changes in bioimpedance as compared to a reference state (and not absolute quantities). Therefore, the technique cannot differentiate between extrapulmonary structures (muscles, thorax, heart, large vessels, spine, etc.) and non-aerated lung tissues - which is a major limitation for the clinical use of information derived from EIT-imaging. Moreover, current EIT-reconstruction algorithms are based on the consideration of a complete circular thoracic shape and do not take into account the body contours and lung borders. The investigators are convinced that EIT-derived dynamic bedside lung imaging can be advanced by morphing computed tomography (CT) scans of the respective thoracic levels with concomitant EIT images - thus enhancing EIT-image information with CT-data. Integrating the anatomy of thoracic shape and lung borders provided by high-spatial resolution multi detector CT-scans (MDCT) with high-temporal resolution EIT has the potential to improve image quality considerably. This data can be used to compute mean EIT-reconstruction models that further offer the possibility to develop novel and clinically meaningful EIT parameters. Therefore, the investigators hypothesize that by integration of CT-scan information of body and lung contours (and by computing different EIT reconstruction models) the current methodological limitations of EIT technology can be overcome.
Study Type
INTERVENTIONAL
Allocation
NA
Purpose
DIAGNOSTIC
Masking
NONE
Enrollment
160
One continous electrical impedance tomography (EIT) measurement per subject of approximately 5 minutes duration (2 min prior to MDCT scanning, during end-inspiratory MDCT acquisition and 2 min after MDCT scanning)
Electrical Impedance Tomography Finite Element Model
Based on CT-derived thorax, lung and heart contours we propose to calculate human finite element models (FEM) for EIT analysis
Time frame: approximately 1 year through study completion
height
Time frame: at the time-point of inclusion
weight
Time frame: at the time-point of inclusion
gender
Time frame: at the time-point of inclusion