The purpose of this study is to determine whether a left ventricular rapid pacing using the valve delivery guide-wire in transcatheter aortic valve implantation (TAVI) reduces the overall procedure duration in comparison with the conventional method.
Use of temporary pacing via a right ventricular lead in TAVI is still mandatory to ensure transient cardiac standstill while predilatation is performed and the valve is being positioned and deployed. This requires an additional venous vascular access and a pacing catheter which are both likely to generate complications. This study compares the standard right ventricular rapid pacing to a new and simplified technique : a left ventricular rapid pacing is provided via the back-up 0.035 " guidewire. The cathode of an external pacemaker is placed on the tip of the 0.035" wire and the anode on a needle inserted into the groin. Insulation is ensured by the balloon or TAVI catheter.
Study Type
INTERVENTIONAL
Allocation
RANDOMIZED
Purpose
OTHER
Masking
SINGLE
Enrollment
300
Rapid pacing during TAVI is required to ensure transient cardiac standstill while predilatation is performed and the valve is being positioned and deployed. In the right ventricular pacing arm, rapid pacing is provided by a standard right ventricular pacing catheter.
Rapid pacing during TAVI is required to ensure transient cardiac standstill while predilatation is performed and the valve is being positioned and deployed. In the Left ventricular pacing arm, rapid pacing is provided via the valve-delivery guidewire inserted into the left ventricle. The cathode of an external pacemaker is placed on the external end of the guidewire using an alligator clamp. The TAVI catheter provides the necessary insulation. The anode is attached directly to the subcutaneous tissue at the femoral entry site (also using an alligator clamp).
CHU Clermont Ferrand
Clermont-Ferrand, Auvergne-Rhône-Alpes, France
Centre Hospitalier Annecy Genevois
Épagny, Auvergne-Rhône-Alpes, France
Clinique du Tonkin
Villeurbanne, Auvergne-Rhône-Alpes, France
Groupement Hospitalier Mutualiste de Grenoble
Total TAVI procedural duration
Duration of TAVI procedure is calculated from the first puncture to the last sheath removal
Time frame: 1 month
Efficacy of the experimental technique to create a blood pressure drop reaching at least 60 mmHg (Ventricular stimulation efficiency)
Stimulation efficiency is defined as a drop in systolic blood pressure reaching at least 60 mmHg during the prolonged stimulation without loss of capture for more than 30s.
Time frame: 1 month
Incidence of the experimental technique on succes rate of the intervention, fluoroscopy time, radiation exposure, Major adverse cardiovascular event and tamponades (Safety)
Safety includes success of the intervention, fluoroscopy time, radiation exposure, Major adverse cardiovascular event and tamponades
Time frame: 1 month
Incidence of the experimental technique on direct and indirect costs (Cost-effectiveness)
Study costs includes direct costs (material used for the rapid pacing) and indirect costs (medical complications)
Time frame: 1 month
This platform is for informational purposes only and does not constitute medical advice. Always consult a qualified healthcare professional.
Grenoble, Isère, France
Hôpital privé Jacques Cartier
Paris, Massy, France
Clinique Saint-Hilaire
Rouen, Normandy, France
Clinique Pasteur
Toulouse, Occitanie, France
Institut Arnault Tzanck
Saint-Laurent-du-Var, Provence-Alpes-Côte d'Azur Region, France
Institut Mutualiste Montsouris
Paris, Île-de-France Region, France