This study aims to compare the ventilation Distribution between tidal Volume 6ml/kgBW and tidal volume 10ml/kgBW in laparoscopic nephrectomy patients
Approval from Ethical Committee of Faculty of Medicine University of Indonesia was acquired prior conducting the study. Subjects were given informed consent before enrolling the study. Non-invasive blood pressure (NIBP) monitor, electrocardiogram (ECG) and pulse-oximeter was set on the subjects in the operation room. Anesthesia procedure was epidural regional block. After given premedication (midazolam 0.05 mg/kgBW and fentanyl 1-2 ug/kgBW), induced with propofol, 1-2 mg/kgbb, endotracheal tube intubation was done facilitated by atracurium 0.5 mg/kgbb. Mechanical ventilation was set up with volume control mode, (Positive End Expiratory Pressure) PEEP 5cmH2O (5 centimeters of water), O2 fraction (FiO2) 30-50%, target carbondioxide (CO2) 35-45%. Volume tidal was given according to the group (6 mL/kgBW or 10 ml/kgBW). Hemodynamic, ventilation parameter, Electrical Impedance Tomography (EIT) parameter were recorded. If desaturation happened intraoperatively will be managed by increasing FiO2 and recruitment maneuver until oxygen saturation (SpO2) \>95%. Data was analyzed using Statistical Program for Social Sciences (SPSS), for numeric data using unpaired T-test or Mann-Whitney-U test, for categorical data using Chi-square or Fisher Exact Test. Significant value is p\<0.05.
Study Type
INTERVENTIONAL
Allocation
RANDOMIZED
Purpose
SUPPORTIVE_CARE
Masking
SINGLE
Enrollment
30
Tidal volume 6ml/kgBW was given to subjects after endotracheal tube was inserted properly.
Tidal volume 10 ml/kgBW was given to subjects after endotracheal tube was inserted properly.
Cipto Mangunkusumo Central National Hospital
Jakarta, DKI Jakarta, Indonesia
Tidal impedance variation regional (TIV-ROI)
Evaluating ROI values displayed on EIT Dräger PulmoVista® 500 monitor.
Time frame: 2 months
Global End expiratory lung impedance difference (ΔEELI-g)
Global End expiratory lung impedance difference (ΔEELI-g) will be measured by the EIT monitor.
Time frame: 2 months
Regional End expiratory lung impedance difference (ΔEELI- ROI)
Regional End expiratory lung impedance difference (ΔEELI-g) will be measured by the EIT monitor.
Time frame: 2 months
Compliance regional (CR)
Tidal Impedance Variation value divided by atmospheric pressure above PEEP value.
Time frame: 2 months