A cohort observational study to characterise baseline Structured Light Plethysmography (SLP) outputs in infants with bronchiolitis and examine response to treatment using the Thora3DiTM
Viral illness, particularly chest infection causing breathing difficulty in infants and children is the commonest reason for admission to hospital. At present, there are no objective measurements of the degree of breathing difficulty. This is because current objective tests of breathing difficulty requires the patient to cooperate and actively perform the tests. This is not possible in babies and very challenging in young children. SLP is a noncontact, effort independent technique for measuring the rate of breathing, the amount of chest expansion and the relative contribution of chest and abdomen to the work of breathing. Measuring these parameters which are known to vary with increasing breathing difficulty will allow us to make objective assessments of breathing difficulty. This study proposes to validate this technique in babies aged 02 years who are healthy and in babies with clinical viral bronchiolitis. The Investigators intend to demonstrate that the technique is feasible in this young age group and that the investigators will be able to demonstrate clinically valid differences between normal and ill babies and also demonstrate measurable differences with the evolution of the clinical illness.
Study Type
OBSERVATIONAL
Enrollment
60
Both healthy infants and bronchiolitis infants will have their chest movements monitored using Structured Light Plethysmography (SLP) performed by a device (Thora-3 Di) using a projector and two cameras. A light pattern of black and white squares is projected on the child's chest and the cameras record how the shape of this pattern changes with breathing. A computer converts this information to show how the child's chest moves during breathing.
University Hospitals of North Midlands NHS Trust
Stoke-on-Trent, Staffordshire, United Kingdom
Difference in SLP measurements between infants.
Difference in SLP measurements between infants. SLP provides a measure of the chest and abdominal movement (Respiratory effort) of the subjects, the movement signal will be used to quantify clinically relevant tidal breathing parameters such as timing indices: Ti (Time of inspiration), Te ( Time of expiration) and Ttot (Ti+Te). Parameters will be quantified for each recorded SLP signal (averaged) from each infant, and then used to compare between infants with bronchiolitis and healthy babies.
Time frame: Measured upto 7 days
Changes in SLP measurements in infants during their clinical course.
Changes in SLP measurements in infants during their clinical course in hospital. SLP provides a measure of the chest and abdominal movement (Respiratory effort) of the subjects, the movement signal will be used to quantify clinically relevant tidal breathing parameters such as timing indices: Ti (Time of inspiration), Te ( Time of expiration) and Ttot (Ti+Te). For each subject SLP was recorded on a daily basis, this will allow the comparison between the parameters within subject to check the progression of the disease with time
Time frame: Measured upto 7 days
Changes in SLP measurements in infants given additional breathing support.
Changes in SLP measurements in infants during their clinical course in hospital who are given additional breathing support. SLP provides a measure of the chest and abdominal movement (Respiratory effort) of the subjects, the movement signal will be used to quantify clinically relevant tidal breathing parameters such as timing indices: Ti (Time of inspiration), Te ( Time of expiration) and Ttot (Ti+Te). For each subject SLP was recorded on a daily basis, this will allow the comparison between the parameters within subject to check the progression of the disease with time.
Time frame: Measured upto 7 days
This platform is for informational purposes only and does not constitute medical advice. Always consult a qualified healthcare professional.