The purpose of the study is to collect more data about performance and safety of the device called "IrisFITTM PFO occluder". This data will be used to help more patients who will accept treatment with this device in the future. Patients will undergo routine examination, procedure and follow-up. Related data will be collected and kept in a way that patient info is well protected.
This is a Post Market Clinical Follow-up study. Informed consent will be obtained from the patient or from a legally authorized representative of the patient at screening. The patients will be screened (pre-procedure) to determine eligibility for the study. At screening, patients will be assessed for study eligibility by the inclusion/exclusion criteria through their medical history, demographics and transthoracic echocardiography (TTE). Participating patients will have their PFO closed using the IrisFITTM PFO Occluder device. The patients will undergo a clinical examination, electrocardiogram (ECG), clinical laboratory assessment and transthoracic echocardiography (TTE). All periprocedural procedures will be performed according to site´s standard of care.. The efficacy and safety of the devices will be assessed by ECGs, vital signs, physical examination and TTE, which will be done at 1day, at 1month and at 6 months post procedure. Safety will also be assessed at 12 months by telephone visit.
Study Type
INTERVENTIONAL
Allocation
NA
Purpose
TREATMENT
Masking
NONE
Enrollment
85
Cardio Vasculäres Centrum Frankfurt
Frankfurt, Germany
Helmut-G.-Walther-Klinikum
Lichtenfels, Germany
Mater Misericordiae University Hospital
Dublin, Ireland
Adverse device effects during the procedure up to the point of implanting the study device in the PFO, and during completion of the procedure
Adverse device effects during the procedure up to the point of implanting the study device in the PFO, and during completion of the procedure
Time frame: during completion of the procedure
Device related adverse event up to 1 month follow-up
Device related adverse event up to 1 month follow-up
Time frame: 1 month post procedure
Device related adverse event up to 12 month follow-up
Device related adverse event up to 12 month follow-up
Time frame: 12 month post procedure
Rate of accurate device placement
Rate of accurate device placement
Time frame: 6 month post procedure
Incidence of device migration/malfunction
Incidence of device migration/malfunction
Time frame: 6 month post procedure
Successful closure/procedure rate: Proper position of the occluder by imaging, with trivial to small or without residual shunt, 6 month after procedure).
Successful closure/procedure rate: Proper position of the occluder by imaging, with trivial to small or without residual shunt, 6 month after procedure).
Time frame: 6 month post procedure