The aim of the study is to determine the influence of the combined anteversion of acetabular cup and the femoral stem used in total hip arthroplasty on the theoretical and actual range of motion of the hip in three dimensional space.
Ninety patients from the clinics of a single consultant orthopaedic surgeon, who are listed to for total hip arthroplasty will be recruited to the study. They will have their surgery performed by the participating consultant as per his standard practice for the target study patient. This involves using the Excia T cementless stem, the ceramic femoral head, the Plasmafit Plus cementless liner and the Biolox delta acetabular cup all by B Braun Medical Ltd. The participating consultant routinely uses computer aided orthopaedic surgery (CAOS) techniques to implant the stem and the acetabular cup and all study patients will have surgery using these techniques. Participants will have their standard in-patient care and rehabilitation. Standard hospital practice for hip arthroplasty patients is for them to return to the hospital for a post-operative review at three months. During this appointment they will be reviewed by a member of the arthroplasty team and have two radiographs taken, an anterior/posterior view of the full pelvis and a lateral view of the index hip. Study participants will return for the three month post-operative review and be seen by the arthroplasty team as standard, but will not have the two radiographs taken. Instead, they will have a computed tomography (CT) scan taken of the full pelvis. In addition to the standard clinical outcome data collected, Participants will also complete the Harris Hip Score and a range of motion questionnaire. Study participants will also have an additional assessment as part of their three month post-operative review. In the movement analysis laboratory in the Golden Jubilee National Hospital, they will undergo a RoM assessment using clinical movement analysis techniques. During this assessment, participants will be asked to fully flex/extend their hip joint, fully abduct/adduct it, fully internally/externally rotate it and finally fully circumduct it. While performing these tasks, their hip joint movement will be tracked by a number of infrared cameras identifying small reflective markers attached to their body. A computer can convert these data into three dimensional RoM data for further analysis. At the end of their three month post-operative review, the participant's involvement in the study will be complete. The computer used for CAOS is capable of measuring the on-table range of motion (RoM) of the hip. This data will be collected for the purposes of the study. Mathematical methods will be used to determine the theoretical RoM of the hip from the CT scan. The data from the movement analysis session will give the actual RoM. The CT scan will be analysed to determine the inclination and version of the acetabular cup and the torsion of the femoral stem. From this, the combined anteversion (CA) of the cup/stem system will be determined. Comparison will be made between the CA and the actual RoM to determine to what extent, if any, the CA influences the RoM. Comparisons will be made between the on-table RoM and the theoretical RoM, and the actual RoM to assess the accuracy of the methods used to determine the on-table and theoretical RoMs.
Study Type
INTERVENTIONAL
Allocation
NA
Purpose
BASIC_SCIENCE
Masking
NONE
Enrollment
90
This group will have a CT scan at three months post-operatively instead of the two radiographs, an anterior/posterior pelvis view and a lateral hip view, which are standard care. They will also have a RoM assessment session in the movement analysis laboratory in the hospital at the same time point lasting about one hour, which is additional to standard care.
Golden Jubilee National Hospital
Clydebank, West Dunbartonshire, United Kingdom
RECRUITINGActual hip range of movement in degrees measured using clinical movement analysis
Hip RoM in three dimensions measured using clinical movement analysis techniques
Time frame: Three months
Theoretical hip range of movement in degrees calculated from CT scans
Hip RoM in three dimensions determined mathematically from the CT scan
Time frame: Three months
On-table hip range of movement in degrees as measured by the operative navigation computer
Hip RoM in three dimensions measured using the CAOS computer system
Time frame: Intra-operatively
Combined anteversion in degrees of the acetabular cup and femoral stem system measured from CT scans
A measure of the hip implant orientation using the torsion of the stem and the version of the cup
Time frame: Three months
Leg length discrepancy
difference in leg length measured from the CT scan
Time frame: Three months
Oxford Hip Score
Patient reported hip pain and function
Time frame: Three months
EQ-5D
Patient reported quality of life
Time frame: Three months
Harris Hip Score
Clinician assessed hip pain and function
Time frame: Three months
This platform is for informational purposes only and does not constitute medical advice. Always consult a qualified healthcare professional.
Patient satisfaction measured on a five point Likert scale
Patient reported satisfaction with hip
Time frame: Three months
Number of dislocations in cohort
Post-operative dislocations
Time frame: Three months
Number of revisions in cohort
Revision rate
Time frame: Three months
Number of infections in cohort
Post-operative surgical site infections
Time frame: Three months
Operative time in minutes
Length of operation
Time frame: Intra-operative
Blood loss volume
Amount of blood lost
Time frame: Intra-operative
Blood transfusion (Yes/No)
Peri-operative blood transfusion data
Time frame: Intra-operative