Use of catheter ablation for persistent atrial fibrillation (PerAF) remains controversial due to unsatisfactory long-term success rates (15% - 28.4%). The investigators' previous study indicated that the upper area of the left atrium (LA) plays an important role in PerAF, with the LA roof and mitral isthmus appearing to serve as main substrate in progression from PAF to PerAF and maintenance of fibrillatory activities. The investigators therefore hypothesized that AF should not be initiated or sustained if the latter crucial regions for AF maintenance are abolished. This study aimed to describe the efficacy and safety of additional linear ablation on the left atrial anterior wall for PerAF.
Although studies and guidelines have helped establish catheter ablation as preferred treatment for patients suffering from paroxysmal atrial fibrillation (PAF), use of catheter ablation for persistent atrial fibrillation (PerAF) remains controversial due to unsatisfactory long-term success rates (15% - 28.4%). The investigators' study indicated that the upper area of the left atrium (LA) plays an important role in PerAF, with the LA roof and mitral isthmus appearing to serve as main substrate in progression from PAF to PerAF and maintenance of fibrillatory activities. The investigators therefore hypothesized that AF should not be initiated or sustained if the latter crucial regions for AF maintenance are abolished. This was confirmed using a stepwise pure linear ablation protocol, consisting of a line across the LA roof and extending along the anterior wall of pulmonary veins (PV) antrum to mitral valve annulus (MVA) without PV isolation; the approach appeared safe and effective with long-term (5.2 years) follow-up success rate of 40% for PerAF. This study will evaluate efficacy and safety of circumferential pulmonary vein isolation (CPVI) + LA roof linear ablation + LA anterior wall (LAAW) linear ablation combined with high density mapping and contact force sensing techniques for perAF. This study is expected to provide a practical and guided catheter ablation strategy with maximized safety and efficacy through use of contact force sensing technique, which will be accepted by other qualified electrophysiology laboratories.
Study Type
INTERVENTIONAL
Allocation
RANDOMIZED
Purpose
TREATMENT
Masking
SINGLE
Enrollment
214
Additional linear ablation on LAAW using ThermoCool SmartTouch ablation catheter.
China National Center for Cardiovascular Diseases
Beijing, Beijing Municipality, China
RECRUITINGAF recurrence
Freedom from AF at 1 year without any anti-arrhythmic drugs. Recurrent AF is defined as documented AF (through 12-lead ECG or Holter) period lasting \>30 seconds after a 3-month blanking period.
Time frame: From August, 2016 to July 2019. The overall Time Frame for AF recurrence is being assessed up to 36 months.
Acute success rate of AF termination during ablation procedure
Time frame: From August, 2016 to July 2017. The overall Time Frame for AF termination during ablation procedure is being assessed up to 12 months.
Frequency of complications
Time frame: From August, 2016 to July 2017. The overall Time Frame for frequency of complications is being assessed up to 12 months.
Average radiation exposure
Time frame: From August, 2016 to July 2017. The overall Time Frame for average radiation exposure is being assessed up to 12 months.
Frequency of redo procedures
Time frame: From August, 2016 to July 2019. The overall Time Frame for frequency of redo procedures is being assessed up to 12 months.
This platform is for informational purposes only and does not constitute medical advice. Always consult a qualified healthcare professional.