Dysfunctions such as tight stenosis or thrombosis in haemodialysis vascular accesses are the leading cause of hospitalisationand morbidity in chronic haemodialysis patients incurring significant related costs estimated at over one billion dollars in the USA. Dysfunctions of these vascular accesses are generally treated by conventional angioplasty as this is the least invasive procedure, the alternative being revision surgery. Angioplasty uses an inflatable balloon of various diameters. Different types of angioplasty balloons may be needed to break fibrous venous stenosis, in particular high-pressure balloons or cutting balloons. These angioplasty procedures which are often painful during dilation have a high technical success rate but a poor 1-year patency rate. These invasive repeated procedures impair the quality of life of these patients with end-stage renal disease who are on permanent dialysis or awaiting a kidney transplant and for whom vascular access patency is vital. Due to their traumatic effect on the vessel wall, these procedures induce cell proliferation processes that retrigger neointimal hyperplasia the very act of preserving the haemodialysis access is the key factor in development of a new stenosis and hence a vicious circle of stenosis-angioplasty. For the past few years, angioplasty balloons delivering anticancer drugs have been developed. These drugs, generally used in high doses for cancer chemotherapy, are released in small doses on the medical angioplasty devices. During inflation, the local release of the anticancer molecule through the different layers of the vessel wall confers local antiproliferative action without the systemic toxic effects associated with high-dose chemotherapy. These medical devices have demonstrated their efficacy in terms of increase in primary and secondary patency rates on procedures such as coronary artery angioplasty, femoro-popliteal or sub-popliteal artery angioplasty. These drug-eluting balloons (DEBs) are also CE marked with the recommendation of being indicated for AVF anticancerangioplasties, but no randomised multi-centre clinical trial has proven their medical effectiveness, and in particular their contribution in terms of patency rate improvement. However, studies on animal models show significant results regarding efficacy against neointimal hyperplasia and the first single-centre clinical trials on a small sample size appear promising. The key assessment criterion is primary patency of the dilated stenosis at one year defined by patients efficaciously dialysed at one year without re-intervention on the dilated lesion after initial angioplasty. The delay of occurrence of dilation will be considered. Patients that will be non-evaluable for the primary endpointwill be censored at the date of the latest news.
Dysfunctions such as tight stenosis or thrombosis in haemodialysis vascular accesses are the leading cause of hospitalisation (20%) and morbidity in chronic haemodialysis patients incurring significant related costs estimated at over one billion dollars in the USA. Dysfunctions of these vascular accesses are generally treated by conventional angioplasty as this is the least invasive procedure, the alternative being revision surgery. Angioplasty uses an inflatable balloon of various diameters. Different types of angioplasty balloons may be needed to break fibrous venous stenosis, in particular high-pressure balloons (20 atm) or cutting balloons. These angioplasty procedures which are often painful during dilation have a high technical success rate (90-97%) but a poor 1-year patency rate, varying between 26 and 64% depending on the team and a mean rate estimated at 40% for the studies including the larger number of patients, some of whom requiring several procedures. These invasive repeated procedures impair the quality of life of these patients with end-stage renal disease who are on permanent dialysis or awaiting a kidney transplant and for whom vascular access patency is vital. Due to their traumatic effect on the vessel wall, these procedures induce cell proliferation processes that retrigger neointimal hyperplasia the very act of preserving the haemodialysis access is the key factor in development of a new stenosis and hence a vicious circle of stenosis-angioplasty. For the past few years, angioplasty balloons delivering anticancer drugs (Paclitaxel, Sirolimus, Everolimus) have been developed. These drugs, generally used in high doses for cancer chemotherapy, are released in small doses on the medical angioplasty devices. During inflation, the local release of the anticancer (antimitotic) molecule through the different layers of the vessel wall (Paclitaxel is lipophilic and hydrophobic) confers local antiproliferative action without the systemic toxic effects associated with high-dose chemotherapy. These medical devices have demonstrated their efficacy in terms of increase in primary and secondary patency rates on procedures such as coronary artery angioplasty, femoro-popliteal or sub-popliteal artery angioplasty (treatment of angina or lower limb arteriopathy). These drug-eluting balloons (DEBs) are also CE marked with the recommendation of being indicated for AVF anticancerangioplasties, but no randomised multi-centre clinical trial has proven their medical effectiveness, and in particular their contribution in terms of patency rate improvement. However, studies on animal models show significant results regarding efficacy against neointimal hyperplasia and the first single-centre clinical trials on a small sample size appear promising. The key assessment criterion is primary patency of the dilated stenosis at one year defined by patients efficaciously dialysed at one year without re-intervention on the dilated lesion after initial angioplasty. The delay of occurrence of dilation will be considered (censored criteria). Patients that will be non-evaluable for the primary endpoint (death, lost to follow-up…) will be censored at the date of the latest news.
Study Type
INTERVENTIONAL
Allocation
RANDOMIZED
Purpose
TREATMENT
Masking
SINGLE
Enrollment
115
Dilatation by a high-pressure conventional angioplasty balloon untill disappearance of the stenosis obstructive area and achievement of technical success. Then dilatation by a DEB of the same size for 2 minutes.
Dilatation by a high-pressure conventional angioplasty balloon untill disappearance of the stenosis obstructive area and achievement of technical success. Then dilatation either by a shame balloon or by a DEB balloon of the same size for 2 minutes.
Dilatation by a high-pressure conventional angioplasty balloon untill disappearance of the stenosis obstructive area and achievement of technical success. Thenn dilatation by a shame balloon i.e conventional low pression balloon of the same size for 2 minutes.
CHU Bordeaux
Bordeaux, France
Centre Hospitalier Universitaire de Caen
Caen, France
Centre Hospitalier Universitaire de Clermont-Ferrand
Clermont-Ferrand, France
Centre Hospitalier d'Haguenau
Haguenau, France
APHM Hôpital la Timone
Marseille, France
Centre Hospitalier Universitaire de Montpellier
Montpellier, France
Hôpital Européen Georges Pompidou
Paris, France
Centre Hospitalier Universitaire de RENNES
Rennes, France
Centre Hospitalier Universitaire de Toulouse
Toulouse, France
Clinique St Gatien de Tours
Tours, France
Number of patients whose haemodialysis is efficient at 1 year without needing further treatment of the stenotic site after initial angioplasty
assess the primary patency at 1 year after the dilatation of native AVF stenosis with "active" drug-eluting balloons (DEB) compared to conventional "plain" balloons, i.e to compare between the two groups the number of patients whose haemodialysis is efficient at 1 year without needing further treatment of the stenotic site after initial angioplasty.
Time frame: 1 year
primary patency at 6 months
assess the advantages of Drug-Eluting Balloon compared to conventional plain balloon for primary patency at 6 months of the dilated stenosis
Time frame: 6 months
overall primary patency of the Arteriovenous Fistula at 1 year
assess the advantages of Drug-Eluting Balloon compared to conventional plain balloon for overall primary patency of the Arteriovenous Fistula at 1 year (patency including AVF dysfunction in relation to the initial dilated stenosis as well as stenoses distant from the initially treated site)
Time frame: 1 year
assisted primary patency of the dilated stenosis at 1 year
assess the advantages of Drug-Eluting Balloon compared to conventional plain balloon for assisted primary patency of the dilated stenosis at 1 year: Arteriovenous Fistula patency and continuation of efficient haemodialysis sessions with new angioplasties on the initially dilated stenotic site (excluding de-obstruction for complete thrombosis)
Time frame: 1 year
secondary patency of the AVF at 1 year
assess the advantages of Drug-Eluting Balloon compared to conventional plain balloon for secondary patency of the Arteriovenous Fistula at 1 year: Arteriovenous Fistula patency and continuation of efficient haemodialysis sessions also including complete thrombosis de-obstruction procedures
Time frame: 1 year
The minimal diameter of the treated stenosis and the AVF flows
assess the advantages of Drug-Eluting Balloon compared to conventional plain balloon for the minimal diameter of the treated stenosis (Late Luminal Loss) and the Arteriovenous Fistula flows (both criterion being evaluated by Doppler ultrasound and Transonic® after angioplasty, and at 6 months and 1 year follow-up).
Time frame: 1 year
Overall and cardiovascular survival
during analysis in sub-groups, the advantage of these Drug-Eluting Balloons for Overall and cardiovascular survival at 2 and 5 years for all patients and for subgroup of patients with symptomatic peripheral artery disease
Time frame: 5 years