Hypothesis The use of Macintosh blade sized #3.5 (vs Macintosh size #3) would reduce the time required to achieve successful tracheal intubation and improve the glottic view. Study objective The purpose of this research study is to compare 3 different laryngoscope blades (sizes: 3.5, 3.5 and 3) and see if the blades size 3.5 will reduce the time required to achieve successful tracheal intubation and improve the physician's view of the glottis compared to the standard direct laryngoscope using the blade size 3, in patients undergoing lumbar surgery. Primary end point: time to achieve successful tracheal intubation. Secondary end points: glottic view at intubation, number of intubation attempts and effectiveness of the integrated suction in the Inscope Direct Laryngoscope.
Laryngoscopy is a common medical procedure used during elective and emergency intubations. The procedure is performed with either a direct or video laryngoscope with the device selected dependent on tool availability, provider (i.e. anesthesiologist, emergency physician, ENT physician, paramedic, etc.) preference, patient characteristics, and intubation difficulty. The direct laryngoscope technique involves a line-of-sight view from the patient's mouth to vocal cords along the blade of the scope. The direct laryngoscopy technique is the oldest technique associated with intubation. However, despite continuous improvements to direct laryngoscope size and shape since its inception in the late 19th century, no improvement yet addresses one major problem with airway visualization: the provider will experience a difficult intubation if liquids (i.e. gastric content, blood, mucus, etc.) obstruct the view. The Sun-Med GreenLine®/D™ Macintosh is a line of disposable direct Macintosh laryngoscopes. It features a stainless steel blade and polycarbonate light-pipe to direct light into the airway. The handle, with integrated batteries and LED light, and blade are separately packaged prior to use. The GreenLine®/D™ Macintosh line is available in the standard sizes (0, 1, 2, 3, 4) and a new size built to improve blade sizing for many adults 3.5 when a Mac 3 is too short, but a Mac 4 is too large. The GreenLine®/D™ Macintosh does not feature integrated suction. The Inscope Direct Laryngoscope (developed by Inscope Medical Solutions) is a new disposable direct laryngoscope with two integrated and controllable (flow on/off) suction pathways. By integrating controllable suction with two independent pathways into the laryngoscope, the provider is able to select the primary (blade tip) suction pathway to clear secretions ahead of the laryngoscope and the secondary (at blade mid-length, below blade) to prevent and clear fluids that may re-accumulate during the procedure. Integrating the suction into the device prevents the common current practice of "juggling" the current suction catheter and endotracheal (breathing) tube in one hand while holding the patient's airway open with the other hand. While the incidence of aspiration of fluids into the lungs as a result of poor airway fluid management is low, the outcomes associated with this complication are very poor. The Inscope Direct Laryngoscope has been developed as a Macintosh 3.5 sized blade to meet the size requirements of the majority of patients. This assumption is backed up by a trend among disposable direct laryngoscope manufacturers toward the 3.5 blade size, with at least 5 creating a 3.5 blade, including Teleflex, Sun-Med, Flexicare, Mercury Medical, and Curaplex. This study will compare the Inscope Direct Laryngoscope (blade size 3.5) with the currently used standard single-use Sun-Med Greenline/D Macintosh laryngoscopes DL-blade mac size and Sun-Med Greenline/D-blade size 3.5. All Direct Laryngoscopes are considered a Class I exempt device by the FDA. Because the risks associated with laryngoscopes are well known and documented, they are considered a non-significant risk device for studies involving humans.
Study Type
INTERVENTIONAL
Allocation
RANDOMIZED
Purpose
SCREENING
Masking
DOUBLE
Enrollment
5
Patient will be intubated using the DL- Blade MAC size 3
Patient will be intubated using the DL- Blade MAC size 3.5
Patient will be intubated using the Inscope Blade size 3.5
Cedars Sinai Medical Center
Los Angeles, California, United States
Intubation Time (Using a Stopwatch)
Intubation Time: It is the time taken to intubate: from the initial insertion of the laryngoscope blade to the placement of the tracheal tube (approximately 3 minutes). An intubation attempt: It is defined as the insertion of the laryngoscope blade into a patient's mouth, with the objective of inserting an endotracheal tube into the trachea.
Time frame: up to 3 minutes
Glottis Visualization POGO Score
The percentage of the glottis visualized (POGO) score It represents the percentage of glottic opening seen; the score ranges from 0% when none of the glottis is seen to 100% when the entire glottis, including the anterior commissure, is seen.
Time frame: During intubation procedure, up to 1 minute
Time From the Insertion of the Laryngoscope Blade to Confirm w/ CO2 Waveform
The time following the initial insertion of the laryngoscope blade into the mouth to confirm w/ CO2 waveform
Time frame: During intubation procedure, up to 3 minutes
Intubation Attempts
An intubation attempt is defined as the insertion of the laryngoscope blade into a patient's mouth, with the objective of inserting an endotracheal tube into the trachea. The number of intubation attempts in each participant for successful tracheal intubation measured how many times the anesthesiologist attempted to place the tube into the trachea of each patient.
Time frame: 3 minutes
Glottis Visualization Using Cormack Lehane
Grade Description Approximate frequency Likelihood of difficult intubation 1. Full view of glottis 68-74% \<1% 2. a Partial view of glottis 21-24% 4.3-13.4% 2b Only posterior extremity of glottis seen or only arytenoid cartilages 3.3-6.5% 65-67.4% 3 Only epiglottis seen, none of glottis seen 1.2-1.6% 80-87.5% 4 Neither glottis nor epiglottis seen very rare Note: In the analysis of the data collected for 5 participants, there was no differentiation between "2a" and "2b" for a grade of "2."
Time frame: During intubation procedure, up to 1 minute
This platform is for informational purposes only and does not constitute medical advice. Always consult a qualified healthcare professional.