The Prosthesis-to-Annulus Relation I (PAR I) trial is a German multicenter study assessing the relation between the prosthetic GOA and the area of LVOT as potentially new parameter for the prediction of hemodynamic outcome. The results may possibly guide future valve size selection an may allow prediction of functionally relevant PPM (Patient-Prosthesis-Mismatch)
Great debates revolve around the hemodynamic performance of prosthetic tissue valves. It is influenced by the design and the specific sizing strategy. Design determines the actual geometric orifice area (GOA), sizing strategy the actual size of the selected valve. Currently, hemodynamic performance is generally assessed by determining the effective orifice area (EOA, derived from the continuity equation by relating flow velocities and LVOT area). The question whether a prosthesis patient mismatch (PPM) is present is then addressed by relating EOA to body surface area (EOAi). However, this relation may not be reasonable because EOAi relates flow velocity twice to patient-specific anatomic parameters (LVOT area and body surface area) . Considering this potential methodological flaw, debate and confusion regarding PPM is easily understood, despite the fact that, intuitively leaving a gradient behind after aortic valve replacement cannot be irrelevant. Thus a reliable and comparable method to determine the presence of PPM is needed. In PAR I Trial the relation between true prothetic GOA and LVOT area will be assesses as a potentially new parameter for prediction of hemodynamic outcome, to possibly guide future valve size selection (inclusive valve-in-valve) and to allow the detection of functionally relevant PPM. In the trial it will be assessed how anatomic dimensions of patients and implanted valves relate to each other and whether they allow the prediction of hemodynamic outcome.
Study Type
OBSERVATIONAL
Enrollment
304
Herzzentrum Dresden
Dresden, Germany
Asklepios St. Georg
Hamburg, Germany
Department of Cardiothoracic Surgery
Jena, Germany
Hospital Bogenhausen
Munich, Germany
recording of hemodynamic outcome of a aortic valve in mutual dependence of anatomical facts on the basis of echocardiographic parameter
Echocardiographic evaluation of the anatomical facts e.g. Left ventricular outflow area
Time frame: postprocedure before discharge (less than 30 days after implant)
Mortality 30 days after implant
Mortality
Time frame: 30 days
Morbidity 30 days after implant
Morbidity
Time frame: 30 days
This platform is for informational purposes only and does not constitute medical advice. Always consult a qualified healthcare professional.
Herz- und Kreislaufzentrum Rotenburg / Fulda
Rotenburg (Wümme), Germany
Krankenhaus der Barmherzigen Brüder
Trier, Germany
University Hospital of Ulm
Ulm, Germany