The proposed study seeks to compare visual acuity, tomographic outcomes, biomechanical changes and inflammatory profile of normal eyes (matched for age, refraction and corneal thickness) undergoing iDesign and SMILE procedure. The hypothesis is that iDesign may deliver equivalent or better clinical outcomes than SMILE, by removing less tissue and correcting for higher order aberrations.
iDesign is a promising new technique to treat myopia with astigmatism using ocular aberrations measured with a high resolution wavefront sensor.\[1,2\] Early studies with iDesign platform has established its safety and efficacy in correction of myopia with fewer patients reporting night vision problems.\[1,2\] In keratoconus, iDesign has also provided excellent outcomes following collagen crosslinking.3 SMILE is a recent technique that eliminates creation of flap and appears to achieve similar refractive outcomes as conventional LASIK but with less dryness, less inflammation and faster wound healing.\[4,5\] SMILE corrects lower order aberrations only.\[4,5\] Thus, a comparative assessment of iDesign and SMILE is necessary since iDesign can potentially give better visual outcomes with lower volume of tissue removal. If lower volume of tissue is removed, it is also hypothesized that the corneal would be more stable biomechanically.\[5\] Further, SMILE does not provide any correction of higher order aberrations. With the inclusion of higher order aberrations in the iDesign treatment plan, it is hypothesized that both short and long term outcomes will be better with iDesign than with SMILE.
Study Type
INTERVENTIONAL
Allocation
RANDOMIZED
Purpose
TREATMENT
Masking
NONE
Enrollment
100
One group will under go standard LASIK using iDesign platform (J\&J, USA). Visual acuity, tomography outcomes, biomechanical outcomes and inflammation in myopic eyes treated with iDesign and SMILE are proposed to be evaluated under the study.
The other group will undergo SMILE for treatment refractive error (Carl Zeiss, Germany). isual acuity, tomography outcomes, biomechanical outcomes and inflammation in myopic eyes treated with iDesign and SMILE are proposed to be evaluated under the study.
Narayana Nethralaya
Bangalore, Karnataka, India
RECRUITINGChange in visual acuity measured as Logarithm of manifest refraction
Uncorrected and corrected distance visual acuity
Time frame: Post surgery over a period of 1 year
Change in Corneal curvature in Diopter
Optical coherence tomography and Scheimpflug imaging of the cornea will be performed
Time frame: Post surgery over a period of 1 year
Change in deformation of the cornea
Air-puff applanation of the cornea will be used to asses deformation
Time frame: Post surgery over a period of 1 year
Change in ocular surface dryness and/or pain
Assessed by ocular surface discomfort score
Time frame: Post surgery over a period of 1 year
Change in wavefront aberrations described by Zernike Polynomials
Corneal and ocular aberrations
Time frame: Post surgery over a period of 1 year
This platform is for informational purposes only and does not constitute medical advice. Always consult a qualified healthcare professional.