This is a clinical study aimed at demonstrating the safety and product performance of the SoundBite Crossing System. The study shall demonstrate that the SoundBite Crossing System can facilitate passage of a standard guidewire through a Chronic Total Occlusion (CTO) located in the lower extremity arteries without major adverse events related to SoundBite device utilization.
Prospective, multi-center, single-arm, two-phase clinical study. This study will be conducted in two phases. The first phase will consist of ten (10) subjects enrolled and treated using the SoundBite Crossing System with 30 day follow-up. An analysis shall be performed after 10 subjects undergo treatment with the SoundBite Crossing System and complete 30 day follow-up. This analysis shall be utilized to provide insight into product performance and safety. The second phase will consist of up to forty (40) subjects enrolled and treated using the SoundBite Crossing System with 30 day follow-up. An analysis will be generated on this subject cohort after 30 day follow-up is complete.
Study Type
INTERVENTIONAL
Allocation
NA
Purpose
OTHER
Masking
NONE
Enrollment
37
With confirmation that the target vessel is completely occluded by the target CTO lesion, the operator shall initially attempt crossing the proximal end of the target CTO lesion by advancing ShockWireTM device ≥ 1cm. The SoundBite Crossing device can be activated as needed to perform the procedure and may be used for the entire length of the lesion(s).
CHUM - Centre Hospitalier de l'Université de Montreal - Hôtel-Dieu
Montreal, Quebec, Canada
CHUS - Centre Hospitalier Universitaire de Sherbrooke - Freurimont
Sherbrooke, Quebec, Canada
Device Success
Device Success is the primary endpoint for the study. Device Success is defined as the achievement of Technical Success with freedom from Major Adverse Events through 30 day follow-up, per Independent Physician Reviewer (IPR) adjudication.
Time frame: 30 Day follow-up
Technical Success
Technical Success: the ability of the SoundBite Crossing System to facilitate crossing of a target CTO lesion, defined as: The ShockWireTM being advanced by 1cm or more into proximal aspect of target CTO lesion based on angiography; AND Either the ShockWireTM or other commercially available device (e.g. guidewire) is able to cross target CTO lesion. Technical Success shall be assessed at the time of the index procedure after all ShockWireTM devices have been used on the target CTO lesion (if more than one ShockWireTM device was utilized to address the target CTO lesion).
Time frame: At the time of the index procedure