This study will evaluate the performance of a curriculum using medical simulators to train patients with advanced heart failure and their caregivers to master the self-management of ventricular assist devices (a device implanted into the heart to help circulate the blood). The investigators expect this training will improve self-management skills, and reduce VAD-related infections and re-hospitalizations. In addition to providing innovative training to the patients and their caregivers, the study will advance our knowledge of the effects of simulation-based training on patient self-management and safety.
Study Type
INTERVENTIONAL
Allocation
RANDOMIZED
Purpose
HEALTH_SERVICES_RESEARCH
Masking
NONE
Enrollment
143
The SBML training group will first 1) watch the VAD video, then 2) participate in a SBML intervention using the simulator for a) driveline exit site sterile dressing changes; b) performing controller self-tests; c) changing power sources; d) troubleshooting emergent VAD-related malfunction; and e) recognizing specific signs and symptoms requiring immediate contact with the VAD team.
Northwestern University
Chicago, Illinois, United States
Comparisons of VAD-care Checklist Assessment on the Patient and Written Examination Scores Between SBML and Usual Training Groups
The investigators will compare the performance of the SBML intervention group to the usual VAD training group during actual VAD care activities (controller change, power source change and dressing change) plus a written examination. Only caregivers were assessed on dressing change as patients do not independently complete this task.
Time frame: 3 months
Infections and Re-hospitalizations up to 3 Months After VAD Implant
All VAD related driveline infections and re-hospitalizations between the SBML intervention group as compared to the usual VAD training group
Time frame: 3 months after discharge
Self-management Skill Decay in the Five Domains
The investigators will measure the change in skill decay on the patient from 0 (time of implant), one and three months using VAD self-management checklists (controller change, power source change and dressing change) throughout the study period.
Time frame: 1 month and 3 months after discharge (*1 month SBML-trained only)
Comparisons of Self-confidence Between Groups
Simulation-based Mastery Learning (SBML) Trained and Usual Trained Patient and Caregiver Reported Self-Confidence (0=very low confidence to 100=very high confidence) before Discharge Testing on Five VAD Skills.
Time frame: 3 months