The spreading of transcatheter aortic valve implantation has paradoxically increased the spectrum of indications for balloon aortic valvuloplasty. Balloon aortic valvuloplasty is currently used as destination therapy for patients excluded from transcatheter aortic valve implantation, as bridge to transcatheter aortic valve implantation or to surgical aortic valve replacement, or as a stratification tool for selected high-risk patients who cannot be immediate candidates for transcatheter aortic valve implantation. Moreover, it has been recently showed that transcatheter aortic valve implantation without balloon aortic valvuloplasty is encumbered by an increased risk of cerebral embolization. However, balloon aortic valvuloplasty has a complication rate comparable to transcatheter aortic valve implantation, mainly related to access site or temporary pacemaker implantation. Thus, a transradial mini-invasive approach with rapid pacing through the 0,035 inch left ventricular support wire could be extremely appealing.
Consecutive patients with severe aortic stenosis with indication to aortic balloon valvuloplasty will be enrolled. An ad hoc informed consent for the procedure will be obtained from all patients. This is a prospective observational study. The Investigators will include patients where aortic ballloon valvuloplasty is attempted by radial access and without temporary pacemaker implantation. The aim is to register and monitor the effectiveness and safety of this approach. Details regarding management of radial access and pacing with 0.035 wire can be found in the references reported below. The primary endpoint will be the 30-day occurence of minor and major vascular complications according VARC 2 classification. The safety endpoint will be the absence of intra- or periprocedural major complications in transradial balloon aortic valvuloplasty, namely balloon entrapment or compartment syndrome requiring surgical intervention. The feasibility endpoint will be a procedural success rate ≥90%. The efficacy endpoint will be a reduction of the mean invasive gradient \>30%. At baseline, Handgrip strength test will be performed and angiography of the instrumented arm will be performed at the beginning and at the end of the procedure. All patients will be prospectively followed-up for at least 30 days and all adverse events will be recorded. All patients will be assessed also for frailty according the clinical frailty scale (CFS). During the 30-day follow-up visit two independent blinded operators will evaluate radial artery patency by ultrasonography and perform handgrip strength test in in both arms in all patients.
Study Type
OBSERVATIONAL
Enrollment
361
Mini-invasive balloon aortic valvuloplasty consisting in transradial access
Rapid pacing using the 0.035-in. retrograde left ventricular support wire
University Hospital of Ferrara
Cona, Ferrara, Italy
Pia Fondazione Panico
Tricase, Lecce, Italy
Ospedale Bassini
Cinisello Balsamo, Milano, Italy
AOU San Luigi Gonzaga
Orbassano, Torino, Italy
Ospedale di Conegliano
Conegliano, Treviso, Italy
AOU di Ancona
Ancona, Italy
AOU di Bologna
Bologna, Italy
Ospedale Morgagni Pierantoni
Forlì, Italy
Ospedale Misericordia
Grosseto, Italy
Ospedale Vito Fazzi
Lecce, Italy
...and 7 more locations
Vascular complications
Cumulative occurrence of major and minor bleeding complications according the VARC-2 classification
Time frame: 1 month
Transradial balloon aortic valvuloplasty major complications
Balloon entrapment, compartment syndrome requiring surgical intervention
Time frame: 1 month
Adverse events
Cumulative occurrence of death, stroke, coronary occlusion, coronary dissection, moderate-severe aortic regurgitation, severe hypotension requiring intervention, pericardiocentesis, definitive pace-maker implantation
Time frame: 1 month
Major vascular complications
Cumulative occurrence of major bleeding complications according the VARC-2
Time frame: 1 month
Minor vascular complications
Cumulative occurrence of minor bleeding complications according the VARC-2
Time frame: 1 month
Radial artery occlusion
Cumulative occurrence of radial artery occlusion
Time frame: 1 month
Radial artery occlusion
Cumulative occurrence of radial artery occlusion
Time frame: 24 hours
This platform is for informational purposes only and does not constitute medical advice. Always consult a qualified healthcare professional.