The use of lidocaine, as an anesthetic drug, during implantation of an implantable cardioverter-defibrillator(ICD)will not result in a clinically significant alteration of the defibrillation threshold during ICD placement.
Summary: The purpose is to observe the incidence of successful defibrillation on the first attempt during implantation of an implantable cardioverter-defibrillator (ICD) among patients who receive a standard dose of intravenous lidocaine (for attenuation of pain associated with propofol injection) versus patients who do not receive an intravenous lidocaine dose. During implantation of an ICD, defibrillation threshold (DFT) testing is performed. DFT is calibrated as the lowest energy delivered by the ICD that will successfully terminate malignant arrhythmia. Lidocaine, a routine anesthetic agent, is also identified as an antiarrhythmic drug. Experimentally, lidocaine has been shown to increase thresholds during DFT' testing due to the drugs dual effect. The rationale behind this project is that the lidocaine may yield falsely elevated DFT, resulting in higher calibration of the ICD device. This alteration can affect ICD battery and overall ICD life. Comparisons between study groups may elucidate effects of IV lidocaine on DFT.
Study Type
INTERVENTIONAL
Allocation
RANDOMIZED
Purpose
PREVENTION
Masking
DOUBLE
Enrollment
19
A one time bolus of lidocaine 0.5 mg/kg iv will be administered just prior to IV propofol injection,then successful defibrillation will be ascertained
A control group will get an IV bolus of 0.9% NS just prior to IV bolus of propofol, then successful defibrillation will be ascertained
Hahnemann University Hospital
Philadelphia, Pennsylvania, United States
Incidence of successful defibrillation on first attempt with 10-12 joules.
These patients will receive a standard dose of intravenous lidocaine (for attenuation of pain associated with propofol injection) versus patients who do not receive an intravenous lidocaine dose. Outcome is to have a success defibrillation within the first attempt.
Time frame: Through study completion but no longer than 1 year
Incidence of failure to defibrillate at higher energy levels.
This outcome occurs when research team fails to defibrillate on any attempt.
Time frame: Through study completion but no longer than 1 year
Defibrillation threshold (DFT) for subjects who fail to defibrillate at the initial 10-12 joules.
This outcome occurs when research team fails to defibrillate on first attempt.
Time frame: Through study completion but no longer than 1 year