This study is evaluating the effect of adding a high dose of simethicone to the standard polyethylene glycol preparation for screening colonoscopy in the quality of the preparation , adenoma detection rate and withdrawal times.
A proper bowel preparation is key to a thorough and safe colonoscopy. Several factors affect the mucosal visualization during colonoscopy, and consequently the quality of such evaluation. Undoubtedly, this can have unfavorable implications like missed lesions. One of the most commonly encountered scenarios is the presence of multiple bubbles that interfere with mucosal visualization. When this occurs, simethicone (an antifoam agent used to reduce bloating when ingested orally) is injected through the colonoscope to eliminate the bubbles and get a clear view of the mucosa. A few studies have used oral simethicone in conjunction with oral preparation agents (PEG, magnesium citrate, sodium phosphate) in an attempt to improve the quality of the preparation. Unfortunately these studies have not used the exact same preparation agent with and without simethicone, making it difficult to draw conclusions on its efficacy. However, it is important to understand that simethicone is not intended to decrease the amount of stool in the colon, and it's purpose is to decrease the amount of bubbles interfering with the visualization of the mucosa provided that there is no stool present . Furthermore, it is unclear if adding simethicone to a standard bowel preparation makes a significant difference in key aspects of screening colonoscopy such as adenoma detection rate or withdrawal times. This prospective randomized controlled, observer blinded study at Texas Tech University Health Sciences Center in El Paso, aims at studying the effect of simethicone on the overall colon preparation as well as on adenoma detection rate and withdrawal times.
Study Type
INTERVENTIONAL
Allocation
RANDOMIZED
Purpose
SCREENING
Masking
DOUBLE
Enrollment
268
Patients will be assigned randomly to take Simethicone Solution plus polyethylenglycol
Patients in this arm will be randomly assigned to take polyethylenglycol as their regular bowel preparation
Texas Tech university Health Sciences Center El Paso
El Paso, Texas, United States
Adenoma Detection Rate
The number of adenomatous polyps removed at colonoscopy
Time frame: 25 minutes
Withdrawal Times
Amount spent withdrawing the scope during the colonoscopy
Time frame: 6-10 minutes
Colon Preparation
Boston Bowel Preparation Scale (BBPS): scale that rates the quality of the colon preparation based on the amount of stool present. 0:solid stool that cannot be cleared; 1:areas not well seen due to residual stool and/or opaque liquid; 2:small fragments of stool and/or opaque liquid, but mucosa seen well; 3:no residual stool or opaque liquid seen. Score determined by adding the score of each individual segment of the colon (right side, transverse and left side). Scores range from 0 to 3 in each segment, therefore, a total composite score ranges from 0 (poor) to 9 (excellent). Bubble Score (BS): scale that rates the amount of bubbles present in the colon. 0:no or minimal bubbles; 1:bubbles covering up to half the luminal diameter; 2:bubbles covering the circumference of the lumen; 3:bubbles filling the entire lumen. Score determined the same way as BBPS score but in this case a total score of 0 is excellent and 9 is poor.
Time frame: 25 minutes
Intraprocedural Use of Simethicone
The number of colonoscopies during which the endoscopist requested simethicone to be flushed through the endoscope.
Time frame: 6-10 minutes
This platform is for informational purposes only and does not constitute medical advice. Always consult a qualified healthcare professional.