The aim of this study is to assess the efficacy of transcutaneous electrical stimulation of the pharyngeal dilator muscles in patients with obstructive sleep apnoea in the community compared to usual care, and follow the patients for three months, as well as to assess compliance of non-invasive electrical stimulation of the upper airway dilator muscles in obstructive sleep apnoea patients over time and evaluate the control of symptoms and improvement in quality of life.
Obstructive sleep apnoea is highly prevalent, with the obesity epidemic increasing the problem. The best treatment for uncomplicated and moderate-severe OSA remains CPAP therapy. However, long-term adherence to treatment with CPAP is poor and there are few alternatives. Electrical stimulation of the dilator muscles of the upper airway has been shown to reduce nocturnal apnoeas significantly using an invasive approach, hypoglossal nerve stimulation, as well as by non-invasive transcutaneous stimulation. Although non-invasive transcutaneous stimulation may not be as effective as CPAP therapy in many OSA patients it could be an important option to treat some of the large number of patients who fail CPAP and might also be of use in those whose OSA is not judged sufficiently severe to warrant CPAP. The investigators propose a study to use a transcutaneous electrical stimulation device in selected patients with OSA who do not tolerate CPAP therapy following assessment of the upper airway. Participants will undergo a baseline sleep study (polysomnography/home-based respiratory polygraphy). Following minimisation for gender (male/female) and OSA severity (mild/moderate-severe) they will be randomised into active treatment arm (transcutaneous electrical stimulation) or usual care (ongoing CPAP therapy). Patients will be treated over a period of 3-months in the community, re-assessed (including polysomnography/home-based respiratory polygraphy) and the results will be compared against usual care, ongoing CPAP therapy. This study will help to prepare a definitive multi-centre randomized controlled trial using the non-invasive method of upper airway stimulation in OSA. The primary aim of this study is to assess efficacy and generate an accurate sample size estimation, test the subjective willingness of patients to use and objectively determined compliance with the treatment over a long period, as well as to specify the drop-out rate. The improvement in sleep apnoea will be the primary outcome measures. The symptomatic response, feasibility of the method, including compliance, comfort, adverse events, will be the secondary outcome measure. An ad-hoc analysis will be performed in the responder group (improvement in the apnoea-hypopnea index (AHI) by \>50% from baseline OR improvement in the 4% oxygen-desaturation index (ODI) \>25% from baseline OR AHI/4%ODI \<5/hour at follow up).
Study Type
INTERVENTIONAL
Allocation
RANDOMIZED
Purpose
TREATMENT
Masking
SINGLE
Enrollment
56
The device needs to be started by pressing the 'on' button. Once the device is turned on the current intensity can be increased by pushing the '+' button and lowered by pushing the '-' button. When a comfortable skin sensation is felt the patients should press the '-' button once more. At that time the device stimulates with a low current which is not felt but provides a neuromuscular tone to the muscles whilst asleep. The device is kept on all night and in the morning taken off with the hydrogel and disconnected. Once disconnected it should be turned off by pressing the 'off' button.
CPAP will be applied according to usual clinical care, the follow up will be organised in the same way as the active intervention group.
Guy's & St Thomas' NHS Foundation Trust
London, United Kingdom
Apnoea Hypopnoea Index
AHI
Time frame: 3 months
Epworth Sleepiness Scale
ESS (0-24 points)
Time frame: 3 months
Oxygen Desaturation Index
4%ODI (x hour-1)
Time frame: 3 months
Usage of treatment
Usage per night (average hours)
Time frame: 3 months
Compliance with treatment
Percentage of nights used (%)
Time frame: 3 months
Acceptance of device
Visual analogue scale (points, 0-10)
Time frame: 3 months
Sleep related quality of life
FOSQ
Time frame: 3 months
Snoring
Percentage of the night (%)
Time frame: 3 months
Genioglossus contraction
Ultrasound (thickness, mm)
Time frame: 3 months
General quality of life
EQ-5D
Time frame: 3 months
This platform is for informational purposes only and does not constitute medical advice. Always consult a qualified healthcare professional.
Anatomy of upper airway
Endoscopically identified diameter (mm)
Time frame: at baseline