This study is being conducted to evaluate the ability of a light emitting diode (LED) study device's ability to raise the temperatures on flank tissue to a similar level compared to an approved laser device (SculpSure by Cynosure). Laser treatments have been shown to reduce fat in the flanks by heating the fat cells and causing them to burst. The contents of the cells are then cleared naturally by the body.
This is an open-label, feasibility study comparing the tissue temperature profile of a 950 nm LED device and a 1060 nm diode laser for non-invasive lipolysis of the flanks. The study will enroll up to 10 subjects requesting non-invasive lipolysis of the flanks. Each subject will receive a single treatment with each device on opposite flanks. Tissue temperatures in the treated areas will be recorded at various tissue depths and compared. Subjects will be asked to assess their discomfort and pain of the study treatment using a 10 cm visual analog scale (VAS). In addition, the safety (number of treatment related adverse events) of the LED device will be compared to the reference device at the time of treatment and one week later.
Study Type
INTERVENTIONAL
Allocation
NA
Purpose
DEVICE_FEASIBILITY
Masking
NONE
Enrollment
10
Device to be used in aesthetic and cosmetic procedures which consists of a console and an applicator belt that delivers the treatment LED to the subject's skin.
FDA approved laser device that has been shown to reduce fat in the flanks by heating the fat cells and causing them to burst. The contents of the cells are then cleared naturally by the body.
Sadick Research Group
New York, New York, United States
Temperature Profile Comparison of the LED Device as Compare to the Reference Device (Diode Laser) at Various Tissue Depths
Immediately (within 2 minutes) after treatment of the area, 3 sterile thermocouple needles of different lengths (9.5-14 mm), will be inserted into the center of each applicator footprint. Temperature readings from each thermocouple needle will be recorded.
Time frame: At time of treatment
Visual Analog Scale (VAS)
Subjects reported level of discomfort and pain after treatment with LED and Laser applicators on a 10 cm horizontal line on which the patient's pain intensity is represented by a point between the extremes of 'no pain at all' (value of 0 cm) and 'worst pain imaginable' (value of 10 cm).
Time frame: Time of treatment