One lung ventilation (OLV) is required during thoracic procedures such as lung and esophagus surgery. three technique can be employed. (1) placement of a double-lumen bronchial tube (DLT); (2) use of a single-lumen tracheal tube (SLT) in conjunction with a bronchial blocker; (3) insertion of a conventional SLT into a main bronchus. Flexible fiberoptic intubation with SLT is well established technique for anticipated or unexpected difficult intubation. But, little is known about flexible fiberoptic intubation with DLT. The investigators compared insertion time over fiberoptic bronchoscope between SLT with bronchial blocker and DLT in patients undergoing thoracic surgery.
Study Type
INTERVENTIONAL
Allocation
RANDOMIZED
Purpose
DEVICE_FEASIBILITY
Masking
DOUBLE
Enrollment
89
fiberoptic intubation with single lumen tube and bronchial blocker
fiberoptic intubation with double umen tube
Ajou universiry hospital
Suwon, Gyeonggi-do, South Korea
insertion time
time from insertion of bronchoscope into mouth to tube placement at trachea or bronchus
Time frame: at anesthesia induction