This study will: 1. validate MRI motility method with concomitant perfused manometry method in healthy adult participants. 2. measure exploratory endpoints of interest including GI fluid volumes in 21 adult healthy volunteers studied twice.
The gastrointestinal (GI) environment where drug products dissolve has not been studied in detail due to limitations, especially invasiveness of existing techniques. Hence little in vivo data on GI fluids and motility is available to improve relevance of predictive dissolution models and bench dissolution techniques. Recent advances in magnetic resonance imaging (MRI) methods could provide novel data and insights. On-going studies at the University of Michigan and at the University of Nottingham, using advanced, validated, quantitative MRI techniques have already shown that GI fluid (water) volumes can be measured. The classical method for measuring GI motility is via a manometric method involving intubation, but it is possible to measure GI motility with MRI. Based on our MRI motility pilot data and on the literature available, this study aims to test the main hypotheses that in healthy adult participants the new MRI method has the potential to replace current manometric study protocols and will allow a simultaneous measurement of gastrointestinal motility and fluid volumes in the gut during the fasted state. This will establish a solid and unprecedented base of in vivo results upon which to base advances in oral pharmaceutical product science. For this initial study, the study objectives are therefore: 1. To validate the MRI motility method with concomitant perfused manometry method in healthy adult participants. 2. To measure exploratory endpoints of interest including GI fluid volumes. Twenty one adult healthy volunteers will participate in this replicated study. We will pass a thin perfused manometry tube via the nose into the gut of the participants and then take MRI images of abdominal areas while bowel motility is being measured via a tube manometric method to see how they compare. We will be able also to measure the volume of fluids in the gut.
Study Type
OBSERVATIONAL
Enrollment
20
We will carry out serial cine MRI of the bowel. At the same time we will record perfused manometry readings of the bowel in healthy adult participants.
Nottingham Digestive Diseases Centre
Nottingham, United Kingdom
Stomach MRI motility
Area under the curve (AUC) of the stomach motility contractions (in mm×second) measured by MRI.
Time frame: Over set time bins and recorded for up to 4 hours
Stomach perfused manometry motility
Area under the curve (AUC) of the stomach motility contractions (in mmHg×second) measured by perfused manometry
Time frame: Over set time bins and recorded for up to 4 hours
This platform is for informational purposes only and does not constitute medical advice. Always consult a qualified healthcare professional.