The reported risk of nonreassuring fetal heart trace following neuraxial analgesia is 3-23%. This variability may be due to fluid and oxytocin management prior to and during the initiation of neuraxial analgesia. The study hypothesis is that decreasing the oxytocin infusion rate by 50 % prior to initiation of combined spinal epidural analgesia will cause a reduction in the incidence of adverse fetal heart rate changes.
Oxytocin is used in labor and delivery to increase the frequency of contractions and augment uterine contractile strength, thereby establishing a regular pattern of labor. However, the administration of exogenous oxytocin in the presence of an uncoordinated labor pattern confers a risk for an increase in uterine contraction frequency, resulting in inadequate relaxation periods. This leads to an increase in the basal tone of the uterus, which may lead to a tetanic contraction with the risk of decreased uteroplacental blood flow and fetal hypoxemia. Previous studies investigating low- versus high-dose oxytocin for induction or augmentation of labor have had conflicting results on the effect on fetal heart rate abnormalities. One of the limitations of these studies is that the labor analgesia was not standardized. The combination of low-dose combined spinal epidural analgesia and the high/low dose oxytocin have not been evaluated. One of the proposed mechanisms for nonreassuring fetal heart a tracing after initiation of analgesia is that the pain relief from neuraxial analgesia causes a decrease in catecholamine release by the sympathetic nervous system. The subsequent decrease in the circulating epinephrine concentration contributes to an increase in uterine tone, as epinephrine is a potent tocolytic agent. The increased tone, in turn, leads to a decrease in placental blood flow, and eventually fetal bradycardia. The primary outcome of this study is the incidence of non-reassuring fetal heart rate tracings within the first 60 minutes after the placement of combined spinal epidural analgesia
Study Type
INTERVENTIONAL
Allocation
RANDOMIZED
Purpose
TREATMENT
Masking
TRIPLE
Patients randomized to the half dose oxytocin group will have the oxytocin infusion reduced to 50 % prior to placement of combined spinal epidural for labor analgesia
University of Iowa Hospitals and Clinics
Iowa City, Iowa, United States
RECRUITINGMedical College of Wisconsin
Milwaukee, Wisconsin, United States
NOT_YET_RECRUITINGIncidence of non-reassuring fetal heart rate tracings
Fetal heart rate tracings will be examined for 30 minutes before and 60 minutes after the initiation of combined spinal epidural analgesia
Time frame: 1.5 hours
Effect of oxytocin dose on duration of 1st and 2nd stage of labor
The effect of the intervention on the duration of labor
Time frame: 24 hours
Mode of delivery
The effect of the intervention on the rate of spontaneous vaginal delivery, instrumental vaginal delivery and cesarean delivery
Time frame: 24 hours
This platform is for informational purposes only and does not constitute medical advice. Always consult a qualified healthcare professional.
Enrollment
730