Nine to 30% of the population suffers from gastro-esophageal reflux disease (GERD) - suggestive symptoms (heartburn, regurgitation, chest pain, chronic couch, sore throat). Proton pump inhibitor (PPI) is usually the first line treatment. However 20 to 60% of patients have persistent symptoms on proton pump inhibitor. Complementary examinations are then required to determine the cause of persistent symptoms (non compliance to treatment, persistent esophageal acid exposure despite proton pump inhibitor, non acid reflux, reflux hypersensitivity, functional symptoms, rumination syndrome…). The gold standard to detect reflux episodes in patients on proton pump inhibitor therapy is 24-h ambulatory esophageal pH-impedance monitoring. Esophageal High Resolution Impedance-Manometry might help to determine gastro-esophageal reflux disease mechanisms especially when performed post prandially. Further some publications demonstrated that the number of reflux episodes detected during the post prandial period might be well correlated to the total number of reflux episodes recorded during 24 h. The hypothesis of this study is that 1-hour post prandial esophageal High Resolution Impedance-Manometry might be useful to diagnose gastro-esophageal reflux disease and can replace in some instances 24-h esophageal pH-impedance monitoring. Therefore the aim is to compare the number of reflux episodes detected with esophageal High Resolution Impedance-Manometry performed during 1-h post prandial period to the total number of reflux episodes detected during 24-h ambulatory esophageal pH-impedance monitoring.
Study Type
OBSERVATIONAL
Enrollment
9
Esophageal high resolution impedance manometry (HRIM) consists of introducing a transnasal probe to record esophageal contractility (manometry), bolus transit (impedance) but also the occurrence of reflux episodes. Ambulatory 24-h pH-impedance monitoring consists of recording the occurrence of reflux episodes by introducing a transnasal catheter into the esophagus. After inserting the transnasal HRIM probe and the pH-impedance catheter, both HRIM and 24-h pH-impedance recordings are started. The patient is instructed to eat a meal that induces reflux symptoms (the patient brings his own meal). One hour the end of the meal, the HRIM probe is removed. The patient is discharged at home and the 24-h pH-impedance monitoring is continued. The patient is coming back 24-h after catheter insertion to stop the pH-impedance recording and remove the catheter.
Exploration Fonctionnelle Digestive, Hôpital Edouard Herriot, Lyon, France
Lyon, France
High Resolution Impedance Manometry
Number of reflux episodes detected on high resolution impedance manometry during the one hour following the meal
Time frame: 1 hour
24-h pH-impedance
Number of reflux episodes detected on 24-h ambulatory esophageal pH-impedance monitoring
Time frame: 24 hour
This platform is for informational purposes only and does not constitute medical advice. Always consult a qualified healthcare professional.