Clinical monitoring is the most common method of adjustment of the appropriate level of general anesthesia. However, the episodes of intraoperative awareness are still reported, suggesting that clinical observations may not be sufficient in some cases. The objective of the study was to compare the efficacy of clinical and instrumental neuromonitoring with auditory evoked potentials in intraoperative analysis of the proper level of general anesthesia. The patients scheduled for elective surgery were included into the study, and randomly divided into two groups. Patients in the first group (TIVA group) underwent intravenous, in the second group (VA group) underwent volatile anesthesia. The adequacy of anesthesia was analyzed with standard clinical parameters. All the participants were instrumentally monitored with AAI index. After the anesthesia patients received a questionnaire with the questions regarding possible intraoperative awareness.
Study Type
INTERVENTIONAL
Allocation
RANDOMIZED
Purpose
PREVENTION
Masking
DOUBLE
Enrollment
208
The monitoring of the adequate level of general anesthesia was performed both clinically and instrumentally.
Department of Anesthesiology and Intensive Therapy
Warsaw, Poland
Changes in AAI values in selected (16) time points.
Time frame: T1: after premedication, just before the onset of anesthesia; T2: 30 seconds after intravenous administration of propofol; T3: just before the endotracheal intubation; T4: 60 seconds after the endotracheal intubation; T5: 5 minutes after the endotracheal