Obstructive sleep apnea (OSA) is a sleep related breathing disorder, affecting approximately 10% of adults. Mandibular advancement oral appliances (OAM) are an effective treatment for OSA, however, long term use has shown to lead to changes in teeth positioning and jaw alignment (bite changes), which has resulted in some patients stopping treatment. It is becoming common clinical practice for doctors to prescribe the use of repositioning splints to help reduce the bite changes associated with using OAM. However, this has not been studied in a clinical trial. This study will compare the bite changes between patients using OAM alone against patients using a morning repositioning splint in addition to OAM. Other variables, such as oral health, the size of mandibular advancement, and treatment adherence will also be measured to determine if they have an effect on the bite changes associated with OAM use. By understanding the key the factors that influence the bite changes associated with OAM use and potentially validating a technique to reduce these changes, this study will improve the clinical practice of Dental Sleep Medicine, leading to improved health outcomes for OSA patients.
Mandibular advancement oral appliances (OAM) are an effective treatment for obstructive sleep apnea (OSA). However, prolonged OAM treatment leads to significant changes in occlusion for the majority of patients. As such it is not uncommon to find changes in occlusion and the resulting decrease in quality of life in long-term users of oral appliances to be cited as a reason for discontinuing OAM treatment. Understanding the determinants of occlusal changes and clinical strategies to minimize or prevent them are essential to the practice of Dental Sleep Medicine, where treatment success is predicated on high levels of adherence. Morning Repositioners or alternative oral appliances/splints that counteract the muscle splinting of the mandible in a forward postured position have been advocated by some practitioners as a means of minimizing the occlusal changes associated with OAM treatment. However, this has not been studied in a prospective clinical trial. The proposed study is a single-blinded prospective randomized controlled trial at three clinical centers, with the specific aim of assessing the effectiveness of mandibular repositioning splint use on minimizing the occlusal changes associated with OAM treatment. Secondary aims include also determining the effects of periodontal disease, treatment adherence, and magnitude of mandibular advancement on occlusal changes associated with OAM treatment. 90 OSA patients will receive OAM treatment following standard practices. A titration period of two months will be used to adjust the position of mandibular advancement for each patient, which will involve clinical follow-up visits at a minimum of 1 week, 1 month and 2 months after initiation of OAM treatment. Each participant will be randomly assigned to either the treatment or control group. The treatment group will receive a mandibular repositioning splint to wear for a minimum of 1 hour in the mornings following removal of OAM. A positive control group will receive no additional splint, and but will be managed using standard practices, including jaw stretching exercises as needed. A second negative control group consisting of 15 healthy adults not undergoing any oral appliance treatment will also be included. Prior to receiving treatment, participants will undergo a baseline assessment where demographic, anthropometric, and specific periodontal health data will be collected. All measurements will be repeated at a minimum of 18 and 36 months after appliance insertion, with routine follow-up appointments and adherence data collected every six months. To directly address the primary aim of this study, occlusal variables will be measured by a combination of methods including analysis of digitized dental models, cephalometric analysis and intra-oral radiography bone level measurements. Secondary outcome variables to assess the effectiveness of morning mandibular repositioning splint therapy will include average OAM adherence (hours/night), quality of life (Functional Outcomes of Sleep Questionnaire, FOSQ), and change in mandibular incisor root length and attachment loss. Adherence will be measured by compliance monitors embedded in the oral appliance and mandibular repositioning splints.
Study Type
INTERVENTIONAL
Allocation
RANDOMIZED
Purpose
SUPPORTIVE_CARE
Masking
SINGLE
Enrollment
105
The Morning Repositioner is a hands-free bite deprogrammer designed to help return the patient's jaw back to its pre-treatment centric position.
Mandibular Advancement Oral Appliances are dental splints used to keep the jaw in an advanced position, opening the upper airway during sleep.
University of British Columbia
Vancouver, British Columbia, Canada
RECRUITINGChange in Overjet
The change in the extent of horizontal (anterior-posterior) overlap of the maxillary central incisors over the mandibular central incisors, measured from digital dental model analysis.
Time frame: Data collected at 0, 18 and 36 months after appliance insertion.
Treatment Adherence
Adherence will be measured by the DentiTrac smart chip (Braebon Medical Corporation, Kanata, Canada) embedded in the oral appliance and mandibular repositioning splints. The adherence will be measured in hours per night and nights per week.
Time frame: Data collected every 6 months after treatment commencement, up to 36 months.
Quality of Life using Functional Outcomes of Sleep Questionnaire (FOSQ-10)
FOSQ-10 measures functional status and difficulty in performing everyday activities via 10 questions. The range of scores for any question is from 1 to 4. There is also a 0 score option for participants who do not engage in a particular activity for other reasons, in which case the question will be excluded. There are 5 subscales that measure: general productivity, activity level, vigilance, social outcomes, and intimacy and sexual relationships. To obtain the total score, a mean-weighted item score is computed for those subscales with more than one item. To calculate a mean-weighted item score calculate the mean of the answered items with responses \> 1 for each subscale. The total score is then derived by calculating the mean of the subscale scores and multiplying that mean by five. Total score ranges between 5 and 20. Higher scores indicate better functional status.
Time frame: Data collected at 0, 1, 2, 18 and 36 months after appliance insertion.
Daytime Sleepiness
Evaluation of OSA specific fatigue using Epworth Sleepiness Scale (ESS) questionnaire. ESS measures daytime sleepiness via 8 questions that ask about daytime sleepiness during common everyday conditions. The potential range of scores for any questions is from 0 to 3. Higher values represent worse outcomes. Their are no subscales for ESS. The answers to the questions are all summed up. Total score ranges between 0 and 24. A score above 10 indicates daytime sleepiness with higher scores indicating more sleepiness.
Time frame: Data collected at 0, 1, 2, 18 and 36 months after appliance insertion.
Change in Overbite
Using digital dental model analysis to evaluate the change in the extent of vertical (superior-inferior) overlap of the maxillary central incisors over the mandibular central incisors, measured relative to the incisal edges.
Time frame: Data collected at 0, 18 and 36 months after appliance insertion.
Dental Crowding
Changes in dental crowding, measured by digital dental model analysis.
Time frame: Data collected at 0, 18 and 36 months after appliance insertion.
Intermolar Distance
Changes in distance between molars, measured by digital dental model analysis.
Time frame: Data collected at 0, 18 and 36 months after appliance insertion.
Intercanine Distance
Changes in distance between canines, measured by digital dental model analysis.
Time frame: Data collected at 0, 18 and 36 months after appliance insertion.
Posterior Occlusal Changes
Changes in the number of posterior teeth with open occlusal contacts, measured from digital dental model analysis.
Time frame: Data collected at 0, 18 and 36 months after appliance insertion.
Anterior Occlusal Changes
Change in the number of anterior teeth in crossbite, measured from digital dental model analysis.
Time frame: Data collected at 0, 18 and 36 months after appliance insertion.
This platform is for informational purposes only and does not constitute medical advice. Always consult a qualified healthcare professional.