Comparison between interlocking multi-twisted wires and Eight figure of sternum closure post open heart surgery in egptian patients
Comparison between interlocking multi-twisted wires and Eight figure of sternum closure post open heart surgery in egptian patients Midline sternotomy, first described by Milton in 1887 \[4,7,8\] remains the most popular technique of cardiac exposure because of its quick and easy performance, excellent access to the heart and great vessels. Effective prevention methods for disruption and infection of median sternotomy continue to be debated. The most important factor in preventing PSWC is a stable sternal approximation, as bony union depends on adequate reduction and immobilization of the stern costal junctions. Strict adherence of preoperative aseptic technique is crucial. Careful attention to homeostasis and meticulous surgical technique remain the mainstays of prevention and must include precise sternal alignment and stable closure. While biomechanical studies appear to be valid, their general value is limited Different sternal closure techniques 1. Trans-sternal/peristernal wiring 2. Bilateral and longitudinal parasternal running wires (described by Robicsek) 3. Double wires 4. Steel band 5. Figure of eight The figure-eight closure is described as faster, simpler, and more reliable than its trans-sternal counterpart; with only oblique forces sutures are less likely to loosen or fracture the sternum. The advantage of figure-eight closure is that it allows oblique and horizontal angle of shearing forces instead of direct perpendicular forces. Thus these wires are less likely to loosen or fracture . 6. Interlocking multi-twisted wires One of recent way in closure of sternal gives more stabilization. At least 6 wires have to be passed. The wires should run around the sternum in the intercostals spaces except in the manubrium where it has to be passed through the bone . Adjacent wires on the surgeon's side are wrapped around each other. The wires on the surgeon's side are then pulled towards the assistant so that the sternum is re-approximated. Alternatively the surgeon can also pull the wires at the assistant's side towards himself or herself approximating the sternum. Adjacent wires on the assistant's side are then wrapped around each other. The wrapped wires on both sides are then wrapped around each other the wrapped wires are then twisted around with a twister, closing the sternum tightly and the ends buried 6- Alternative techniques Techniques utilizing lateral sternal support are first-line options in preventing SD and wound infections. The need to provide lateral reinforcement of the sternum has led to the development of several techniques, such as A-the use of lateral staples and lateral plates B-H-shaped titanium plates C- Reinforced sternal closure system D-thermo reactive clips E- Rigid plate fixation change The purpose of this report was to analyze (I) the efficacy of most used ways in sternal closure in our center ( interlocking multi-twisted wires and Eight figure )for the prevention of Post sternal wound complication in adult egyptian patients and find the way more efficient in sternal closure.
Study Type
OBSERVATIONAL
Enrollment
40
One of many ways in cloure of sternal give more stabilization. At least 6 wires have to be passed. The wirs should run around the sternum in the intercostals spaces except in the manubrium where it has to be passed through the bone . Adjacent wires on the surgeon's side are wrapped around each other. The wires on the surgeon's side are then pulled towards the assistant so that the sternum is re-approximated. Alternatively the surgeon can also pull the wires at the assistant's side towards himself or herself approximating the sternum. Adjacent wires on the assistant's side are then wrapped around each other. The wrapped wires on both sides are then wrapped around each other The wrapped wires are then twisted around with a twister, closing the sternum tightly and the ends of the are burried
The figure-eight closure is described as faster, simpler, and more reliable than its trans-sternal counterpart; with only oblique forces sutures are less likely to loosen or fracture the sternum. The advantage of figure-eight closure is that it allows oblique and horizontal angle of shearing forces instead of direct perpendicular forces. Thus these wires are less likely to loosen or fracture
Assiut University
Asyut, Egypt
RECRUITINGHealing of the sternum
Duration of complete healing of the sternum :By 1. Radiological (chest x-ray ant-post view and lat view in first 6 weeks post-operative 2. Clinical examination in first 6 weeks post operative
Time frame: 60 days
rate of wound infection
way less liable to infect wound either skin infection or wound dehiscence
Time frame: 30 days
mobilization
Early mobilization after surgery till returning to normal movement including freely arm movement
Time frame: 45 days
Time of procedure
time taken by each way in sternal closure
Time frame: 45 days