Heart disease symptoms are a frequent reason of consultation in general medical practice. Only a few general practitioners are equipped with a 12 lead Electrocardiography (ECG) whereas this test is extremely useful for diagnosis orientation in cases of cardiac diseases.Cardiosecur allows the realization of a 15 or 22 leads ECG with only 4 electrodes connected to a smartphone or a tablet with an automatic interpretation function. The goal of the study is to evaluate the diagnostic value of Cardiosecur device regarding cardiac symptoms in family practice.
This study will be a multicenter, single arm, non randomized trial testing the incremental diagnosis value of Cardiosecur ECG regarding cardiac disease in general care. Ten general practitioners will be given a Cardiosecure ACTIVE device with a tablet and perform an EKG to their consecutive patients who meet the inclusion criteria. Inclusion criteria * Recent cardiovascular symptom \< 7 days (chest pain, dyspnea, palpitation, heart failure or transient loss of consciousness) or physical examination leading in possible cardiac cause. * Aged over 18 years * signed the informed consent * A questionnaire regarding the diagnosis orientation based on the patients' symptoms and physical examination will be given to GPs before and after the ECG realization and automatic interpretation to evaluate whether the ECG modified the diagnosis. If the GP need further exploration to conclude or if the patient is oriented to an hospital or a specialist, the reference diagnosis will be defined at the end of these explorations. Otherwise, the diagnostic will be defined at the end of the GP consultation. * A questionnaire regarding the ease of use of the Cardiosecure device will be filled by the patients. * Time for ECG realization will be recorded. * All the ECG and their automatic interpretation will be stored anonymously according to bioethics laws and then reviewed by 2 experienced cardiologists blinded to the results of the automatic interpretation. The interobserver reproducibility as well as the comparison with the Cardiosecur automatic interpretation will be analyzed.
Study Type
OBSERVATIONAL
Enrollment
338
Cardiosecur allows the realization of a 15 or 22 leads ECG with only 4 electrodes connected to a tablet with an automatic interpretation function
Unnamed facility
Aire-sur-la-Lys, France
Unnamed facility
Chenôve, France
Unnamed facility
Cysoing, France
Unnamed facility
Dijon, France
Unnamed facility
Iteuil, France
Unnamed facility
Montreuil-sur-Mer, France
Unnamed facility
Poitiers, France
Unnamed facility
Roubaix, France
Unnamed facility
Vervins, France
Performance of ECG Cardiosecur
Proportion of correct diagnosis before and after Cardiosecur
Time frame: Baseline
This platform is for informational purposes only and does not constitute medical advice. Always consult a qualified healthcare professional.