The purpose of this study is to find out if a PET/MR scan in combination with standard MRI and CT scans can improve the early detection and treatment of patients with prostate cancer.
High risk prostate cancer patients will undergo C11-Choline PET/MR whole body fusion scan and pelvic mpMRI for accurate staging. The PET/MR imaging findings, including the primary lesion with the prostate bed and pelvic lymph nodes, will be correlated with the histopathologic result. Researchers aim to provide accurate one-stop shopping opportunity in diagnosis and staging of high risk prostate cancer using the C11-choline PET/MR scan.
Study Type
INTERVENTIONAL
Allocation
NA
Purpose
DIAGNOSTIC
Masking
NONE
Enrollment
19
C-11 choline PET tracer, One dose, totally 12-14 millicurie (mCi), intravenous administration while patient is lying on the table.
Single dose of Gadavist® (Gadobutrol, Bayer) at no more than 0.1 mmol/kg will be administrated intravenously.
C11-PET/MR and pelvic mpMRI scan for prostate cancer.
Mayo Clinic in Arizona
Scottsdale, Arizona, United States
Uptake Value of C11-choline
Measured by maximum standardized uptake value (SUVmax) of indexed lesions. SUV is calculated as ratio of concentration of tissue reactivity divided by dose at time of injection divided by body weight.
Time frame: Baseline
Number of Lesions Showing C11-Choline Uptake
Measured by the mean number of lesions to show C11-Choline uptake.
Time frame: Baseline