Aim of this study is to investigate the effects of an Oxymizer pendant nasal cannula in hypoxemic patients with idiopathic pulmonary fibrosis during walking.
Patients will be recruited during an inpatient pulmonary rehabilitation program. They will perform three shuttle walk tests on three consecutive days (see below). While performing those tests, the patient's prescribed oxygen flow rate is applicated either through the conventional nasal cannula (CNC) or the Oxymizer.On the first day, patients perform an incremental shuttle walk test to determine maximum walking speed using a conventional nasal cannula. On two consecutive days, patients will perform two endurance shuttle walk tests at 85% of the maximum incremental shuttle walk test speed. Supplemental oxygen will be provided via nasal cannula at the prescribed oxygen flow rate. Patients will be randomly assigned to perform one test with the Oxymizer and the other one with a conventional nasal cannula.
Study Type
INTERVENTIONAL
Allocation
RANDOMIZED
Purpose
TREATMENT
Masking
SINGLE
Enrollment
22
Supplemental oxygen is provided by an Oxymizer pendant nasal cannula.
Supplemental oxygen is provided by a conventional nasal cannula.
Schön Klinik Berchtesgadener Land
Schönau am Königssee, Germany
Endurance shuttle walk test distance
Distance patients walk during an endurance shuttle walk test
Time frame: at baseline, at isotime of endurance shuttle walk test and at the end (maximum 20 min) of endurance shuttle walk test
oxygen saturation
measured by Sentec Digital Monitoring System
Time frame: at baseline, at isotime of endurance shuttle walk test and at the end (maximum 20 min) of endurance shuttle walk test
heart rate
measured by Sentec Digital Monitoring System
Time frame: at baseline, at isotime of endurance shuttle walk test and at the end (maximum 20 min) of endurance shuttle walk test
breathing frequency
measured by NoxT3 device
Time frame: at baseline, at isotime of endurance shuttle walk test and at the end (maximal 20 min) of endurance shuttle walk test
carbon dioxide pressure
transcutaneously carbon dioxide pressure measured by Sentec Digital Monitoring System
Time frame: at baseline, at isotime of endurance shuttle walk test and at the end (maximum 20 min) of endurance shuttle walk test
time to desaturation
time (seconds) is measured until oxygen saturation drops below 90% or 85 % respectively
Time frame: From beginning of endurance shuttle walk test until the oxygen saturation reaches defined thresholds, or ESWT reaches maximum time frame of 20 minutes