This study aims to evaluate the safety and efficacy of new ablation catheter developed by MEDICAL TAEWOONG for the treatment of pancreatic premalignant and early malignant cystic lesion. The ablation is performed using EUSRA needle and radiofrequncy waves under ultrasound imaging. The method will be exaimened on patients who are candidates for surgical intervention and to examine the ability of the method to serve as an alternative to surgical intervention.
In recent years, local and non-invasive intervention methods have been attempted to eliminate or at least reduce the growth of pancreatic lesions. Over the past two years there has been considerable but not successful experience in ablation (burning) of lesions by direct alcohol injection and / or other drugs into the cyst through the EUS. To date, treatment has been performed in three groups of patients in a clinical trial and has shown clinical success from 33% to 70%. However, it should be noted that there is a large incidence of treatment failure and also complications such as pancreatitis. An interesting alternative to surgical intervention is the local destruction of the cyst by radio waves ENDOSCOPIC RADIOFREQUENCY (RF). This is a familiar local method that works by releasing heat that causes necrosis and disappearance of the lesion.High efficacy and high safety profile were reported for this method; 90% of the cases showed disappearance of of metaplasia by the follow-up of 5 years and 80% disappearance of dysplasia (both early and advanced) followed by two and a half years. In addition, in recent years EMCISION has developed a catheter called ENDO HBP HABIB. It is a thin RF probe that can be inserted through work channels of all types of endoscopes and cholangioscopes. The depth of the penetration of heat and energy intensity is in accordance with the resistance of the tissue being treated, and the device operates under the computerized control of an ultrasound device with high resolution. This method showed success in short-term follow-up in preliminary research.The technical difficulty of this therapeutic method is related to the limitation of the ability to position itself precisely by inserting the catheter through the EUS needle.In order to overcome the difficulty of operating HABIB PROBE, MEDICAL TAEWOONG, recognized worldwide and Israel as an advanced endoscopic equipment company, developed in cooperation with STARMED an RF needle called EUSRA, which works in conjunction with a VIVO COMBO generator. The function of the generator is to provide up to 200 watts of energy to activate the electrode. The needle can be directly inserted into the pancreas lesion while controlling EUS. At the tip of the needle is a probe that releases the energy at 50W for 10 seconds or 40W until the white bubbles appear in a sonographic image.In recent years, two cases of successful treatment have been reported. In both cases, treatment of neuroendocrine cancer showed good initial results. The first study was performed on a 76-year-old patient with a neuroendocrine tumor.CT performed about one month after the procedure showed complete disappearance of the lesion without any complications. The second study was performed in six patients with an average age of 62. The average diameter of lesion was 3.8 cm. The procedure was successful when two patients felt abdominal pain followed. There were no bleeding events and pancreatitis.This year, a multicenter study was conducted in France in patients with neuroendocrine tumors and cystic lesions in the pancreas, testing the safety and initial efficacy of the method and monitoring for up to 12 months. The study was conducted in a group of 30 patients.In 6 patients with endocrine tumors there was complete disappearance of the lesions, in 3 patients there was a decrease in the diameter of the lesions by more than 50% and in one patient the treatment failed. In 7 of 8 patients with cystic tumors, walled nadies disappeared and in 5 out of 10 patients cystic tumors disappeared. Prophylactic treatment of antibiotics and NSAIDs (anti-inflammatory drugs) and empty the cyst fluid before the procedure led to a dramatic reduction in complications (3.5%). Three patients experienced mild abdominal pain without signs of inflammation successfully treated with paracetamol. (study not yet published).
Study Type
INTERVENTIONAL
Allocation
NA
Purpose
TREATMENT
Masking
NONE
Enrollment
20
At the tip of the needle there is a probe that releases the peripheral energy in a continuous and continuous manner. The method is a long 50W power release for 10 seconds or 40W until white bubbles appear in a sonographic image. Materials that come into contact with the body: electrode and grounding surfaces
Incidence of adverse and serious adverse events
The number of subjects with post EUS-RFA-related adverse events including: Fever \>38C (will be measured in celcius)
Time frame: up to one month post-procedure
Incidence of adverse and serious adverse events
The number of subjects with post EUS-RFA-related adverse events including: Pancreatitis as measured by an increase of at least 3 times in serum amylase (units/liter) in the initial 72 hours post-procedure
Time frame: up to 72 hours post-procedure
Incidence of adverse and serious adverse events
The number of subjects with post EUS-RFA-related adverse events including: Hemorrhage as measured by need for transfusion of packed red blood cells
Time frame: up to 72 hours post-procedure
Incidence of adverse and serious adverse events
The number of subjects with post EUS-RFA-related adverse events including: Perforation as confirmed by abdominal CT
Time frame: up to 72 hours post-procedure
Incidence of adverse and serious adverse events
The number of subjects with post EUS-RFA-related adverse events including: Mortality
Time frame: up to 12 months post-procedure
Absolute disappearance incidence or reduction in lesion size
Direct measuring of lesion diameter and area (in milimeter and milimeter\^2 respectively) during the 12-month blind follow-up by EUS, CT and MRI .
Time frame: up to 12 months post-procedure (3, 6 and 12 months post-procedure)
Absolute disappearance incidence or reduction in lesion size
disappearance of mural nodule inside cyst follow-up by EUS, CT and MRI .
Time frame: up to 12 months post-procedure (3, 6 and 12 months post-procedure)
Technical efficiency of the method
To examine the technical efficiency of the method by estimating the frequency of success in performing the operation according to the protocol, without any mishaps and deviations from the original protocol.
Time frame: during the procedure