The study of this study is to evaluate the age influence on cortical bone strength properties by two methods:HR-pQCT (HighResolution-peripheral quantitativeComputedTomography) and ultrasound. The main objective consists in the evaluation of the age influence on cortical thickness at 1/3 distal radius measured by US.
The study of this study is to evaluate the age influence on cortical bone by two methods: HR-pQCT and ultrasound. 84 patients will be measured. The cohort will be: * 21 women less than 70 * 21 women more than 70 * 21 men less than 70 * 21 men more than 70 Measurement will be performed at radius and at tibia (ultra-distal and distal). For all the sites one measurement will be performed by HR-pQCT to get reference values of thickness and BMDs. For the distal positions and additional measurement will be performed by an innovative ultrasound device that estimates cortical thickness and porosity. The participation to the study implies only a participation of one hour from the patient (30min for HR-pQCT measurements, 30 min for US). The main objectives consist in : * evaluating the age influence on cortical thickness at 1/3 distal radius measured by US * evaluating the age influence on cortical thickness at distal tibia measured by US * comparing porosities values measured by US to vBMD obtained by HR-pQCT * comparing cortical thickness values measured by HR-pQCT at 1/3 distal radius position to ultra-distal radus position and to the tibia * comparing vBMD values measured by HRpQCT at 1/3 distal radius position to ultra-distal radius position and to the tibia
Study Type
OBSERVATIONAL
Enrollment
66
Measurement will be performed at radius and at tibia (ultra-distal and distal). For all the sites one measurement will be performed by HR-pQCT to get reference values of thickness and BMDs. For the distal positions and additional measurement will be performed by an innovative ultrasound device that estimates cortical thickness and porosity.
Cohen-Solal
Paris, Île-de-France Region, France
Cortical parameters measurement
Cortical thickness at distal radius 1/3
Time frame: Inclusion time
Tibia parameters measurement by US
Cortical thickness distal 1/2 tibia obtained by US * ultra-distal and 1/3 distal cortical thicknesses obtained by HR-pQCT * ultra-distal and 1/3 distal vBMD obtained by HR-pQCT
Time frame: Inclusion time
Tibia parameters measurement by HR-pQCT
Cortical thickness distal 1/2 tibia obtained by HR-pQCT * ultra-distal and 1/3 distal cortical thicknesses obtained by HR-pQCT * ultra-distal and 1/3 distal vBMD obtained by HR-pQCT
Time frame: Inclusion time
Porosity measurement
Ultrasonic porosity obtained by HR-pQCT
Time frame: Inclusion time
vBMD measurement
vBMD obtained by HR-pQCT
Time frame: Inclusion time
Cortical parameters measurement
1/3 distal cortical thicknesses obtained by HR-pQCT
Time frame: Inclusion time
Thicknesses measurement
Ultra-distal thicknesses obtained by HR-pQCT
Time frame: Inclusion time
Ultra-distal vBMD measurement
Ultra-distal vBMD and third distal obtained by HR-pQCT
Time frame: Inclusion time
This platform is for informational purposes only and does not constitute medical advice. Always consult a qualified healthcare professional.