Study Purpose: A multicenter prospective study to evaluate the outcome of second breast cancer surveillance with abbreviated breast MR (AB-MR) or ultrasound (US) in addition to annual mammography in women with BRCA1/2 mutation testing Study Scheme: * AB-MR, US, and digital mammography will be performed on the same day and interpreted independently at baseline and then after 1 year. * After completion of study, patients are followed-up for at least 1 year.
For women with a BRCA1/2 mutation who are treated for breast cancer, screening of remaining breast tissue with annual mammography and breast MRI is recommended. For women who met BRCA testing criteria but show an uninformative negative result or a variant of unknown significance (VUS) result, there is no established recommendation for second breast cancer surveillance. Abbreviated breast MRI (AB-MR) is a fast and low-cost examination that show equivalent diagnostic accuracy to that of the standardized dynamic protocol breast MRI. Breast ultrasound (US) can detect additional cancers that are occult on mammography and is indicated in high-risk patients who cannot tolerate MRI. The purpose of this multicenter prospective study is to evaluate the outcome of second breast cancer surveillance with AB-MR or US in addition to annual mammography in women with BRCA1/2 mutation testing. AB-MR, US, and digital mammography will be performed on the same day at baseline and then after 1 year and images will be interpreted independently according to the Breast Imaging Reporting and Data System (BI-RADS) by experienced radiologists. The BI-RADS category 3 or higher is defined as test-positive. The reference standard will be a biopsy or at least 1 year of follow-up.
Study Type
OBSERVATIONAL
Enrollment
1,564
Seoul National University Hospital
Seoul, South Korea
RECRUITINGSensitivity and Specificity (co-primary)
To compare the sensitivity and specificity of AB-MR, US, and mammography for the detection of secondary breast cancer
Time frame: 1 year
Cancer detection rate (CDR)
To compare the CDR (no. of detected cancers/1,000 examinations) of AB-MR, US, and mammography
Time frame: 1 year
Positive predictive value (PPV)
To compare the PPV (no. of detected cancers / no. of positive examinations) of AB-MR, US, and mammography
Time frame: 1 year
Negative predictive value (NPV)
To compare the NPV (no. of detected cancers / no. of negative examinations) of AB-MR, US, and mammography
Time frame: 1 year
Histopathologic characteristics of secondary breast cancers
To describe the histologic type, tumor grade, and molecular tumor subtype of secondary breast cancers detected at AB-MR, US, and mammography
Time frame: 1 year
This platform is for informational purposes only and does not constitute medical advice. Always consult a qualified healthcare professional.