The goals of this study are to (1) develop and refine PET post-processing acquisition procedures, (2) generate preliminary and comparative imaging data for potential clinical trials, and (3) retrospectively evaluate standard of care PET imaging acquisitions by comparison with investigational PET imaging acquisitions.
The prospective portion of study will utilize investigational PET acquisitions in addition to standard of care PET imaging to develop and optimize PET acquisition post-processing techniques as well as to generate preliminary and comparative data for potential clinical trials. These post-processing techniques include but are not limited to visual inspection of lesions, normal tissue, sentinel nodes and imaging artifacts, semi-quantitative analysis including the use of rating schemes, and using various published methods for image post-processing. The PET methodologies we plan to use as part of this study will allow us to obtain morphological, functional and molecular information. Patients receiving a standard of care PET will be asked by study personnel if they are interested in undergoing additional investigational acquisitions before or after their standard of care imaging. If the patient agrees, he/she will remain on the same PET scanner for up to an additional 30 minutes while more images are obtained. Each patient will be imaged for no longer than 2 hours (standard of care imaging and additional investigational imaging). A routine clinical report will be generated for the clinically indicated PET by a nuclear medicine physician. Once this routine clinical PET scan is dictated and finalized, a study team member will obtain the report via IHIS and manually remove all identifiers. This report is being obtained for comparative purposes. All the data being compared will be coded using a unique study number. The retrospective portion of this study will involve the review of pre-existing data from January 1, 2001 through December 5, 2017. The data to be reviewed/analyzed includes PET imaging data that has been previously collected in the course of standard clinical care. The PET imaging acquisitions obtained from the retrospective review will be utilized as a comparison to the investigational images obtained during the prospective portion of this study. The criteria that will be utilized to determine how the retrospective data will be utilized includes the following parameters: type of imaging study, diagnosis, age in decades, gender, and availability of data in the imaging archive.
Study Type
INTERVENTIONAL
Allocation
NON_RANDOMIZED
Purpose
DIAGNOSTIC
Masking
NONE
Enrollment
131
Investigational PET scan as add-on to standard-of-care scan
Review of pre-existing data from January 1, 2001 through December 5, 2017
The Ohio State University Wexner Medical Center
Columbus, Ohio, United States
image quality
assessed by blinded readers
Time frame: through study completion, on average 2-5 years
artifacts
assessed by blinded readers
Time frame: through study completion, on average 2-5 years
lesion detectability
assessed by blinded readers
Time frame: through study completion, on average 2-5 years
image noise
assessed region of interest over target tissue and background
Time frame: through study completion, on average 2-5 years