This study evaluates a novel noninvasive method to dynamically monitor the effect of abdominal aortic aneurysm (AAA) and endovascular treatment of AAA (EVAR) on arterial pulse wave
Abdominal aortic aneurysm (AAA) develops slowly and degeneratively (increasing diameter, wall tension, thinning and decreased wall strength, altered compliance) which affects the aortic pressure and wave reflection. In 50% of cases, AAA rupture may lead to death and 50% of the remaining patients referred to hospital die. This results in high costs and preventable loss of lives. AAA can also be detected by pulse wave (PW) analysis. which could enable development of easy to use, affordable and accurate methodology for the detection of AAAs. The measurement system used in the present study is capable of wireless recording of PWs from several different locations utilizing two different sensor modalities (blood-volume related photoplethysmographic (PPG) PWs and dynamic blood pressure PWs). The objective is to study PWs in the detection of AAA and the effects of endovascular repair (EVAR) and whether adverse effects (i.e. endograft failure) can be detected. It is hypothesized that AAA and failure of the operation can be detected by PW features, especially by printed flexible sensors which will improve the usability, patient comfort and safety (hygiene). The technology could make it possible to screen AAAs at lower costs even in the municipal health centers or by the patients themselves, at similar accuracy, without skilled personnel operating the diagnostic devices and therefore improve the cost effectiveness of AAA screening resulting in significant savings, resource reallocation in the healthcare and also improved patient safety and prevention of deaths. It could also enable patient-centered, comfort follow-up for patients treated by EVAR.
Study Type
OBSERVATIONAL
Enrollment
30
The sensors are noninvasively attached
Tampere University Hospital
Tampere, Finland
RECRUITINGPulse wave change from baseline during EVAR measured by a force sensor
A force sensor node for dynamic pressure-PW measurements is utilized to detect pulse wave
Time frame: 2 hours
Pulse wave change from baseline during EVAR measured by a optical photoplethysmographic (PPG) sensor
Optical photoplethysmographic (PPG) sensor node is used for volume pulse measurements
Time frame: 2 hours
Pulse wave change from baseline after EVAR measured by a force sensor
A force sensor node for dynamic pressure-PW measurements is utilized to detect pulse wave
Time frame: 30 days
Pulse wave change from baseline after EVAR measured by a optical photoplethysmographic (PPG) sensor
Optical photoplethysmographic (PPG) sensor node is used for volume pulse measurements
Time frame: 30 days
Pulse wave change from baseline after EVAR measured by a force sensor
A force sensor node for dynamic pressure-PW measurements is utilized to detect pulse wave
Time frame: 12 months
Pulse wave change from baseline after EVAR measured by a optical
Optical photoplethysmographic (PPG) sensor node is used for volume pulse measurements
Time frame: 12 months