The main objective of this study will be to determine if the dural puncture epidural (DPE) provides superior analgesia and better patient satisfaction when compared to traditional epidurals for cesarean sections, and to also determine if patient satisfaction in the DPE group is comparable to that of the CSE technique.
There are approximately 4 million child birth deliveries in US hospitals per year, and 1.3million of those births are via cesarean section (c-section). With this type of surgery, obstetric anesthesiology plays an important role. The main objective of this study will be to determine if the dural puncture epidural (DPE) provides superior analgesia and better patient satisfaction when compared to traditional epidurals for cesarean sections, and to also determine if patient satisfaction in the DPE group is comparable to that of the CSE technique.
Study Type
INTERVENTIONAL
Allocation
RANDOMIZED
Purpose
TREATMENT
Masking
TRIPLE
Enrollment
57
Using the Arrow Epidural Kit (AK-05560) an epidural will be placed using the LOR to saline or air technique. A 26g Gertie Marx needle will be inserted through the Touhy epidural needle and used to puncture the dura; clear, free flowing CSF will return in the needle, but no medications will be injected. The 26g spinal needle will be removed, and the epidural catheter inserted through the epidural needle 3-5cm in the epidural space. A test dose with 3mL 1.5% Lidocaine with 1:200,000 epinephrine will be used to confirm the absence of intrathecal or intravascular catheter placement. The epidural catheter will then be dosed with 0.5% Bupivacaine in 5mL increments until a T4 dermatome level is reached. Epidural fentanyl 100mcg will be administered during initial dosing, and morphine-PF 3mg will be given via epidural after delivery of the fetus.
Using the Arrow Epidural Kit (AK-05560) an epidural will be placed using the LOR to saline or air technique. The catheter will be inserted 3-5cm in the epidural space. A test dose with 3mL 1.5% Lidocaine with 1:200,000 epinephrine will be used to confirm the absence of intrathecal or intravascular catheter placement. The epidural catheter will then be dosed with 0.5% Bupivacaine in 5mL increments until a T4 dermatome level is reached. Epidural fentanyl 100mcg will be administered during initial dosing, and morphine-preservative free (PF) 3mg will be given via epidural after delivery of the fetus.
Grady Health System (CRN)
Atlanta, Georgia, United States
Percent of patients with Numeric Pain Rating Score (NPRS)<1 in the DPE vs. EPI group
The blinded investigator will visit the patient within 1hour of block placement and ask to select Numeric Pain Rating Score (NPRS) (1-10) during procedure. The 11-point numeric scale ranges from '0' representing one pain extreme (e.g. "no pain") to '10' representing the other pain extreme (e.g. "pain as bad as you can imagine" or "worst pain imaginable"). Scores range from 0-10 points, with higher scores indicating greater pain intensity.
Time frame: 1 hour after procedure
Percent of patients with Numeric Pain Rating Score (NPRS) <3 in the DPE vs. EPI group.
The blinded investigator will visit the patient 3 hours within 1hour of block placement and ask to select Numeric Pain Rating Score (NPRS) (1-10) during procedure.The 11-point numeric scale ranges from '0' representing one pain extreme (e.g. "no pain") to '10' representing the other pain extreme (e.g. "pain as bad as you can imagine" or "worst pain imaginable"). Scores range from 0-10 points, with higher scores indicating greater pain intensity.
Time frame: 1 hour after procedure
Percent of patients with Numeric Pain Rating Score (NPRS)<1 in the DPE vs. CSE group
The blinded investigator will visit the patient within 1hour of block placement and ask to select Numeric Pain Rating Score (NPRS) (1-10) during procedure.The 11-point numeric scale ranges from '0' representing one pain extreme (e.g. "no pain") to '10' representing the other pain extreme (e.g. "pain as bad as you can imagine" or "worst pain imaginable"). Scores range from 0-10 points, with higher scores indicating greater pain intensity.
Time frame: 1 hour after procedure
Percent of patients required rescue analgesia in the DPE vs. EPI group
Additional sedation administered during procedure will be documented.
Time frame: During labor/delivery (up to 24 hours)
This platform is for informational purposes only and does not constitute medical advice. Always consult a qualified healthcare professional.
Using the Arrow Epidural Kit (AK-05560) an epidural will be placed using the LOR to saline or air technique. A 26g Gertie Marx needle will be inserted through the Touhy epidural needle and used to puncture the dura; clear, free flowing CSF will return in the needle and 12mg bupivacaine, 10mcg fentanyl, 200mcg morphine-PF. The 26g spinal needle will be removed, and the epidural catheter inserted through the epidural needle 3-5cm in the epidural space. No epidural test dose will be given immediately compared to the above procedures secondary to intrathecal injection of local anesthetic with this CSE technique. Only after approximately 1 hour after intrathecal injection will a test dose of 3mL 1.5% Lidocaine with 1:200,000 epinephrine will be used to confirm the absence of intrathecal or intravascular catheter placement. The epidural catheter will then be dosed with 0.5% Bupivacaine for the remainder of the procedure if necessary.
Percent of patients required rescue analgesia in the DPE vs. CSE group
Additional sedation administered during procedure will be documented. .
Time frame: During labor/delivery (up to 24 hours)