This study aims to examine the prognostic value of 18 channel amplitude-integrated EEG (aEEG) in comatose cardiac arrest patients The study design is a prospective observational study. Cardiac arrest patients undergoing targeted temperature management (TTM) will participate in the study. Relation of aEEG in each channel with the neurologic outcome at 6 month after return of spontaneous circulation (ROSC) will be evaluated.
Normal trace was defined as continuous cortical activity on the raw EEG scan; in addition, the upper margin of the aEEG scan, referred to as the aEEG maximum, was \>10 μ V, and the lower margin of the aEEG scan, referred to as the aEEG minimum, was \>5 μ V. The Time from ROSC to normal trace (TTNT, hours) is predictor of neurological outcome in these patients. We will evaluate the prognostic values of TTNTs in all aEEG channels.
Study Type
OBSERVATIONAL
Enrollment
78
18 channel aEEG monitoring in comatose TTM-treated patients
Seoul St. Mary's hospital
Seoul, South Korea
Time to normal trace in each aEEG channel
Normal trace was defined as continuous cortical activity on the raw EEG scan; in addition, the upper margin of the aEEG scan, referred to as the aEEG maximum, was \>10 μ V, and the lower margin of the aEEG scan, referred to as the aEEG minimum, was \>5 μ V. The Time from ROSC to normal trace (TTNT, hours) is predictor of neurological outcome in these patients. We will evaluate the prognostic values of TTNTs in all aEEG channels.
Time frame: at day 180
TTNT threshold for neurologic prognostication in each aEEG channel
Using area under the curve (AUC) of each channel aEEG for neurological outcome, we will determine the best TTNT thresholds for good neurological outcome (CPC 1 to 2) in all aEEG channels.
Time frame: at day 180
Alpha delta ratio of each channel aEEG for good neurological outcome (CPC 1 to 2)
The percentage powers in the alpha, theta and delta bands and the ratio of the powers in different frequency bands (i.e., alpha/delta) will be calculated. Finally we will evaluate the prognostic values of these ratios of the different bands.
Time frame: at day 180
Comparison of prognostic value between aEEG and various predictors
We will compare the prognostic performances (i.e., sensitivity, specificity, AUC) for poor neurological outcome (CPC 3 to 5) between EEG and these predictors.
Time frame: at day 180