The guided FNA by endobronchial ultrasound ( Endobronchial Ultrasound guided transbronchial Needle Aspiration or EBUS-TBNA) is a minimally invasive technique with an established role in the staging of lung cancer 1, and in the evaluation of intrathoracic lymph node metastases from extrathoracic primary cancer2 . There is also a role in cases of isolated hilar and mediastinal lymph nodes in which the differential diagnosis includes mostly sarcoidosis, lymphoma and tuberculosis. 3 Various studies have evaluated more recently the diagnostic yield of EBUS-TBNA specifically for sarcoidosis 4 and thoracic lymphoma 5-6. Although there is emerging data supporting the usefulness of EBUS-TBNA in the investigation of these two pathologies, the efficacy results vary according to the target populations and certain parameters. Moreover, although a large randomized study demonstrated e superiority of EBUS-TBNA over conventional bronchoscopic sampling methods \[ bronchoalveolar lavage (BAL) and trans-bronchial biopsies (TBB \] for the diagnosis of sarcoidosis , 7 the results suggest that there is still room for optimizing the performance of EBUS-TBNA \[b\] . In the field of lymphoma, obtaining large enough specimens for adequate subtyping also remains a concern. 8 In order to improve the performance of EBUS -TBNA , new needles have been developed with the aim to provide biopsies for histological evaluation rather than purely cytological. The ViziShot FLEX © (Olympus) 19 gauge needle (19 gauge or 19G) is a large needle, which can provide both tissue and needle aspiration , and has the advantage of being more flexible. For this study, the investigators want to compare the diagnostic yield of EBUS-TBNA using needle ViziShot FLEX 19G (1.11 mm) with that of the standard 22G needle ( NA-201SX; Olympus) , in the investigation of hilar or mediastinal lymphadenopathy suspected to be sarcoidosis or lymphoma.
Study Type
INTERVENTIONAL
Allocation
RANDOMIZED
Purpose
DIAGNOSTIC
Masking
DOUBLE
Enrollment
50
EBUS-TBNA using the ViziShot FLEX 19G needle
EBUS-TBNA using the Vizishot 22G needle (standard)
Centre hospitalier de l'Université de Montréal (CHUM)
Montreal, Quebec, Canada
RECRUITINGDiagnostic yield of EBUS-TBNA
The diagnostic yield of EBUS TBNA with 19G and 22G needle in patients with a final diagnosis of sarcoidosis will be assessed for any difference between the two, using McNemar test on paired proportions.
Time frame: 12 months after enrollment of the last patient.
Ease of use.
Evaluate the ease of use of both types of needles. Using a visual analog scale (from 0 most difficult to 10 very easy to use), ease of use of each needle will be assessed and compared for each lymph node.
Time frame: 1 week after enrollment of last patient.
Specimen quality
Samples will be considered adequate if the cytologic assessment shows lymphocytes and or definite if the specimen shows epithelioid cell granulomas or collection of epithelioid cells with a giant cell (or asteroid body or Schaumann body). The samples will be classified as: diagnostic, adequate but non-diagnostic, non-diagnostic and not adequate, no specimen
Time frame: 1 week after enrollment of last patient
Complications
Complications encountered with both needle sizes will be compared if there is any difference in the rate of complications, specifically pneumothorax, endobronchial bleeding, post-bronchoscopy bleeding, pneumonia, respiratory infection, hospitalization required because of the procedure, respiratory failure, death.
Time frame: 1 month after enrollment of last patient