Phototherapy has served as a primary treatment for hyperbilirubinemia in newborn populations. The light emitted through phototherapy interacts with bilirubin at the skin level to transform it into water-soluble products eliminated in urine and stool. Efficacy of phototherapy relies on the irradiance dispensed at the skin level by the treatment and on the surface area of skin exposed. The purpose of this Investigator-initiated, prospective, two-arm, randomized control investigation is to compare the effect of a novel, newly available, FDA cleared, phototherapy device (Neolight Skylife) with the standard phototherapy treatments used in HonorHealth newborn nurseries (Natus-Neo Blue Blanket and GE Bili Soft Blanket) on healthy, newborns ≥ 35 weeks + 0 days Gestational Age (GA) at the time of birth in the treatment of hyperbilirubinemia. We hypothesize that the unconjugated bilirubin level will be comparably reduced across each treatment arm from baseline to 12 and 24 hour intervals.
This is an investigator-initiated, prospective, two-arm randomized control investigation to examine the mean values in patients' unconjugated bilirubin level for a new, FDA cleared device (Neolight Skylife) with the standard phototherapy treatment. Patient data on unconjugated bilirubin level, pressure ulcer and body temperature will be evaluated at baseline, 12-hours post-intervention, 24 hours post-intervention and at discharge. Neolight Skylife is a compact device that offers phototherapy to infants across all neonatal beds, supplanting multiple, enclosure specific phototherapy devices. Neolight Skylife weighs less than 10 lbs. and is ergonomically designed for portability that allows for easy carrying of the device between beds. Neolight Skylife offers the choice between treatment intensity levels. Neolight Skylife utilizes blue Light-Emitting Diodes (LEDs) to achieve low irradiance of 30 plus or minus 5 μw/cm²/nm, and high irradiance of 45 plus or minus 10, μw/cm²/nm. Neolight Skylife emits light in a narrow bandwidth between 430-475 nm. This light bandwidth corresponds to the spectral absorption of light by bilirubin, and is thus considered to be the most effective for treatment. Neolight Skylife eliminates the risk of UV exposure typically seen with phototherapy treatment through the use of blue LEDs, as this light source does not emit significant energy in the ultraviolet (UV) spectrum. However, as with all phototherapy treatment, protective eye coverings are used to protect the baby's eyes from excessive light exposure.
Study Type
INTERVENTIONAL
Allocation
RANDOMIZED
Purpose
HEALTH_SERVICES_RESEARCH
Masking
NONE
Enrollment
72
Newly FDA approved device
Both devices are considered standard therapy
HonorHealth Scottsdale Osborn Medical Center
Scottsdale, Arizona, United States
HonorHealth Scottsdale Shea Medical Center
Scottsdale, Arizona, United States
Change in unconjugated bilirubin level from pre-test to post-test
heel stick blood draw for unconjugated bilirubin level
Time frame: Assessment of the endpoint will occur at baseline, 12 hours following treatment, and 24 hours following initial treatment or prior to discharge.
Maintain body temperature between 97.3F and 99.3F
monitor body temperature using a temperature monitoring device
Time frame: Assessment of the endpoint will occur at baseline, 12 hours following treatment, and 24 hours following initial treatment or prior to discharge.
Absence of skin irritation or ulceration
visual assessment of the skin for changes
Time frame: Assessment of the endpoint will occur at baseline, 12 hours following treatment, and 24 hours following initial treatment or prior to discharge.