In European countries, colorectal cancer (CRC) represents an important public health problem. It is widely held view that most carcinomas develop from an adenoma-carcinoma progression. Adenoma detection rate (ADR) is a marker of high quality colonoscopy and it was inversely associated with the risk of interval colorectal cancer, advanced-stage interval cancer, and fatal interval cancer after colonoscopy. Although colonoscopy is considered the gold standard for adenoma detection, it has shown some limits, so industry has aimed at increasing detection rate of adenomas providing new technologies, most of witch to detect lesions located in blind spots. ARC Endocuff Vision (AEV), the second generation of Endocuff, represents a new generation of these devices, thus assessing the diagnostic sensibility of ARC Endocuff Vision assisted colonoscopy (EAC) is an interesting challenge. Aim of the study is to compare ADR of EAC versus standard colonoscopy among FIT positive subjects in the context of CRC screening programs.
In European countries, colorectal cancer (CRC) represents an important public health problem. It is widely held view that most carcinomas develop from an adenoma-carcinoma progression. It has been demonstrated that screening with fecal occult blood test (FOBT) significantly reduces mortality for CRC. Currently, population-based CRC screening programs using FOBT have been or are heading towards being implemented in many European countries. Fecal immunochemical test (FIT) has been adopted by most Italian Regions as the standard screening test, with total colonoscopy as diagnostic assessment in subjects resulted FIT positive. A significant impact of FIT-based screening on CRC mortality reduction has been observed in an Italian region after 10 years from screening implementation. Moreover, two studies carried out in a Northern-central area of Italy have shown a reduction in CRC incidence in subjects who attended FIT screening programs as compared to non-attendees. Increasing colonoscopy quality is critical for the screening impact among population. Adenoma detection rate (ADR) is a marker of high quality colonoscopy and it was inversely associated with the risk of interval colorectal cancer, advanced-stage interval cancer, and fatal interval cancer after colonoscopy. ADR is defined as the proportion of colonoscopies during which at least one adenoma can be detected. A polish study showed that ADR was an independent predictor of the risk of interval colorectal cancer after screening colonoscopy. ADR has shown a direct correlation with: operator experience, cecal intubation, quality of bowel preparation, patient sedation, endoscope withdrawal time, presence of flat, depressed or subtle lesions, ability to visualize the proximal side of haustral folds, flexures (blind spots), rectal valves, and ileocecal valves. On the other hand, colonoscopy is considered the gold standard for adenoma detection, but it has shown some limits. Data from colonoscopy studies showed that up to 25% of polyps were missed during colonoscopy and up to 8% of CRCs occurred within 3 years after a previous colonoscopy. Moreover, recent studies have shown that cancers post-colonoscopy are most likely due to missed lesions, rather than being new lesions. For these reasons, industry has aimed at increasing detection rate of adenomas providing new technologies, most of witch to detect lesions located in blind spots. ARC Endocuff Vision (AEV), the second generation of Endocuff, represents a new generation of these devices, thus assessing the diagnostic sensibility of ARC Endocuff Vision assisted colonoscopy (EAC) is an interesting challenge. Previous researches have studied the performance of colonoscope distal attachment devices. More specifically, a 2016 meta-analysis of more than 5,000 patients demonstrates that, compared to traditional colonoscopy, the use of an Endocuff device improves ADR without any adverse effect on procedural efficiency or increased risk of significant adverse events. Moreover, Facciorusso et al. in 2017 assessed only a modest improvement in ADR by using distal attachment devices, especially in low-performing endoscopists, while in 2018 Williet showed, with moderate-quality evidence, an improvement in ADR with EAC without major adverse events, especially for operators with low-to-moderate ADR. Second-generation AEV is a soft plastic cap, to be applied on the top of the colonoscopy. The cap has a propylene-made cylindrical core, with a single row of flexible arms. During the colon intubation procedure the device is nearly invisible, while in the retraction phase the arms begin to work, opening up and pulling the colon walls, stretching convoluted tracts.
Study Type
INTERVENTIONAL
Allocation
RANDOMIZED
Purpose
SCREENING
Masking
SINGLE
Enrollment
2,100
Current standard of care colonoscopy.
Subjects randomized to undergo a colonoscopy procedure with ARC Endocuff Vision will have this device placed on the top of the colonoscope used during their procedure.
Santa Maria del Prato, Local Health Unit 1 Dolomiti, Veneto Region
Feltre, Belluno, Italy
NOT_YET_RECRUITINGSan Martino Hospital, Local Health Unit 1 Dolomiti, Veneto Region
Belluno, BL, Italy
NOT_YET_RECRUITINGMaggiore Hospital, Crema Territorial Health Care Company, Lombardia Region
Crema, Cremona, Italy
RECRUITINGCazzavillan Hospital, Local Health Unit 8 Berica, Veneto Region
Arzignano, Vicenza, Italy
NOT_YET_RECRUITINGScreening Unit, Oncological Network, Prevention and Research Institute
Florence, Italy
RECRUITINGSan Paolo Hospital Company - University Campus
Milan, Italy
NOT_YET_RECRUITINGSant'Antonio Hospital, Local Health Unit 6 Euganea, Veneto Region
Padua, Italy
NOT_YET_RECRUITINGVeneto Tumor Registry, Local Health Unit 4, Veneto Region
Padua, Italy
ACTIVE_NOT_RECRUITINGSanta Maria della Misericordia Hospital, Local Health Unit 5 Polesana, Veneto Region
Rovigo, Italy
NOT_YET_RECRUITINGCa' Foncello Hospital, Local Health Unit 2 Marca Trevigiana, Veneto Region
Treviso, Italy
NOT_YET_RECRUITING...and 2 more locations
Adenoma Detection Rate (ADR)
Comparison of the number of adenomas (ADR) detected per subject between the Endocuff Vision colonoscopy and the standard colonoscopy.
Time frame: Through study completion, an average of 1 year
Patient values
Comparison of ADR according to patient's age, sex, screening history (first or subsequent test) between the standard colonoscopy arm and the Endocuff Vision colonoscopy arm.
Time frame: Day 1
Exam values
Comparison of cecum intubation, patient discomfort (with Visual Analogue Scale -VAS) between the standard colonoscopy arm and the Endocuff Vision colonoscopy arm. The Visual Analogue Scale goes from 1 to 10, where 1 is the absence pain and 10 is severe pain. Number 1 represents the best outcome measure, while 10 is the worst result for this outcome measure.
Time frame: Day 1
Number of lesions
Comparison of polyps number between the standard colonoscopy arm and the Endocuff Vision colonoscopy arm.
Time frame: Day 1
Size
Comparison of polyps size between the standard colonoscopy arm and the Endocuff Vision colonoscopy arm.
Time frame: Day 1
Anatomical site
Comparison of polyps anatomical site between the standard colonoscopy arm and the Endocuff Vision colonoscopy arm.
Time frame: Day 1
Histological diagnoses
Comparison of polyps histological diagnoses between the standard colonoscopy arm and the Endocuff Vision colonoscopy arm.
Time frame: Through study completion, an average of 1 year
Colonoscopist' age
Analysis of the involved colonoscopists' age.
Time frame: Through study completion, an average of 1 year
Colonoscopist' years of experience
Analysis of the involved colonoscopists' years of experience.
Time frame: Through study completion, an average of 1 year
Colonoscopist' specialization
Analysis of the involved colonoscopists' specialization.
Time frame: Through study completion, an average of 1 year
Colonoscopist' number of exams in the previous year
Analysis of the involved colonoscopists' number of exams in the previous year.
Time frame: Through study completion, an average of 1 year
Colonoscopists' ADR in the previous year
Analysis of the involved colonoscopists' ADR in the previous year.
Time frame: Through study completion, an average of 1 year
This platform is for informational purposes only and does not constitute medical advice. Always consult a qualified healthcare professional.