Maternal hypotension during spinal anaesthesia for Caesarean delivery may bring various adverse effects. It is therefore important to closely monitor hypotension during spinal anaesthesia, however current technology does not allow the blood pressure monitoring to respond in timely manner should there be any occurrence of hypotension. The investigators developed an advanced double-intravenous vasopressor automated system (ADIVA) so as to tackle this issue via novel algorithm to control blood pressure more rigorously with more stable haemodynamic profiles.
The incidence of maternal hypotension during spinal anaesthesia for Caesarean delivery is reported to be as high as 70-90%. The potential adverse effects resulting from maternal hypotension are nausea, vomiting, cardiac dysfunction, foetal acidosis and hypoxia. Hypotension during spinal anaesthesia is currently detected using an intermittent blood pressure (BP) monitor cycling and reactive administration of vasopressors upon detection. The use of conventional non-invasive BP monitoring is limited by the time required to inflate and to deflate the cuffs commonly applied to the arm, which subsequently leads to a failure to react in a timely manner to BP changes when they occur. The DIVA system (double-intravenous vasopressor automated system) previously developed helped tackle the limitations associated with the conventional management of hypotension in Caesarean sections under spinal anaesthesia. In a recent randomized controlled trial the DIVA system achieved less incidence of maternal hypotension compared to conventional management, however the side effects in mother and baby were still not fully eliminated. In this proposed study a new algorithm for an advanced DIVA (ADIVA) system will be developed to control BP more rigorously by detecting BP with more stable haemodynamic profiles and thereby improve patient outcomes. The clinical trial will be conducted in 2 phases. The first phase included the use of ADIVA in 76 subjects who undergo spinal anaesthesia for Caesarean delivery to test its safety and efficacy. The second phase was a randomised controlled trial to investigate the use of ADIVA in comparison to the existing DIVA system in 97 patients undergoing spinal anaesthesia for Caesarean section.
Study Type
INTERVENTIONAL
Allocation
RANDOMIZED
Purpose
TREATMENT
Masking
DOUBLE
Enrollment
173
Phenylephrine will be administered with conditions as below: 1. When systolic blood pressure is between 90-110% of baseline, 25mcg phenylephrine will be given either in infusion or bolus if heart rate ≥ 60 beats/min; 2. When systolic blood pressure is less than 90% of baseline, 25 to 75mcg phenylephrine will be given either in infusion or bolus if heart rate ≥ 60 beats/min.
Ephedrine will be administered with conditions as below: 1. When systolic blood pressure is between 90-110% of baseline, 2mg ephedrine will be given either in infusion or bolus if heart rate \< 60 beats/min; 2. When systolic blood pressure is less than 90% of baseline, 2 to 6mg ephedrine will be given either in infusion or bolus if heart rate \< 60 beats/min.
1. When systolic blood pressure (SBP) is 100-110% of baseline, 25mcg phenylephrine (infusion) is given if heart rate ≥ 60 beats/min, and 2mg ephedrine (infusion) is given if heart rate \< 60 beats/min; 2. When SBP is 90-100% of baseline, 25mcg phenylephrine (infusion or bolus) is given if heart rate ≥ 60 beats/min, and 2mg ephedrine (infusion or bolus) is given if heart rate \< 60 beats/min; 3. When SBP is 80-90% of baseline, 50mcg phenylephrine (infusion or bolus) is given if heart rate ≥ 60 beats/min, and 4mg ephedrine (infusion or bolus) is given if heart rate \< 60 beats/min; 4. When SBP \< 80% of baseline, 75mcg phenylephrine (infusion or bolus) is given if heart rate ≥ 60 beats/min, and 6mg ephedrine (infusion or bolus) is given if heart rate \< 60 beats/min.
DIVA system works as below: 1. When systolic blood pressure is between 90 to 100% of baseline, 25mcg phenylephrine (bolus) will be given if heart rate ≥ 60 beats/min, whereas 2mg ephedrine (bolus) will be given if heart rate \< 60 beats/min; 2. When systolic blood pressure is less than 90% of baseline, 50mcg phenylephrine (infusion or bolus) will be given if heart rate ≥ 60 beats/min, whereas 4mg ephedrine (infusion or bolus) will be given if heart rate \< 60 beats/min.
KK Women's and Children's Hospital
Singapore, Singapore
Number of events of Hypotension occurrence
Systolic blood pressure less than 80% of baseline systolic blood pressure
Time frame: 1 day (during cesarean delivery)
Number of events of Hypertension occurrence
Systolic blood pressure more than 120% of baseline systolic blood pressure
Time frame: 1 day (during cesarean delivery)
Number of events of Nausea and vomiting occurrence
Nausea and vomiting during and after cesarean delivery
Time frame: 1 day (during and after cesarean delivery)
This platform is for informational purposes only and does not constitute medical advice. Always consult a qualified healthcare professional.