The chronic stress of police work may reduce human performance through increases in anxiety, depression, pain, and insomnia. Land's End VR may teach mindful meditation that is associated with reduced anxiety, depression, pain, and insomnia. tACS may produce similar effects to Selective Serotonin Reuptake Inhibitors (SSRIs) without the side effect risks of SSRIs by stimulating neurotransmitter production and modulating the default mode network, resulting in reduced anxiety, depression, pain, and insomnia. These two technologies have not been investigated as interventions among police officers. Therefore, we propose a pilot randomized waitlist-controlled crossover trial of the feasibility and efficacy of Land's End VR and tACS among police officers.
Study Type
INTERVENTIONAL
Allocation
RANDOMIZED
Purpose
DIAGNOSTIC
Masking
NONE
Enrollment
45
TACS- A regulated class of transcranial alternating current stimulation (tACS), called Cranial Electrotherapy Stimulation (CES) by Fisher Wallace Laboratories (FWL) is FDA-Cleared to treat depression, anxiety, and insomnia (Proof of FDA clearance and 510k provided in the appendix). FWL tACS delivers weak non-invasive electrical stimulation (1-4 milliamps at 15, 500, and 15,000 Hz) to the frontal/temporal brain regions by electrodes placed above the temples. Land's End Virtual Reality Game Meta-analyses show Virtual Reality (VR) is an effective non-pharmacological method that reduces obstacles to human performance such as pain, insomnia, anxiety, sleep deprivation, and a variety of other stress responses.
Garland PD
Garland, Texas, United States
Numeric Rating Scale (NRS)
The Numerical Rating Scale (NRS) has been validated as a measure of pain intensity and is one of the most commonly used measures in assessing pain. The NRS asks patients to rate their pain severity on a 0 to 10 scale, with 0 being "no pain" to 10 being "so severe that you can't stand it."
Time frame: Change in score Assessed at Baseline, 2 weeks and 4 weeks.
Insomnia Severity Index (ISI)
The Insomnia Severity Index (ISI) is a 7-item, self-report instrument that assesses the severity of insomnia. The ISI has adequate reliability and validity and is frequently used in randomized controlled trials of sleep interventions. A 5-point Likert scale is used to rate each item (e.g., 0 = no problem; 4 = very severe problem), yielding a total score ranging from 0 to 28. The total score is interpreted as follows: absence of insomnia (0-7); sub-threshold insomnia (8-14); moderate insomnia (15-21); and severe insomnia (22-28).
Time frame: Change in score Assessed at Baseline, 2 weeks and 4 weeks.
The Patient Health Questionnaire 8 (PHQ-8)
The PHQ-8 is a brief self-report measure of major depressive disorder. The PHQ-8 is considered to be valid measure of depression for population-based studies and clinical populations with a cut off score of equal or greater than 10 as the diagnostic for current depression. The PHQ-8 is derived from the PHQ-9 by removing the last question regarding suicide assessment.
Time frame: Change in score Assessed at Baseline, 2 weeks and 4 weeks.
Primary Care Posttraumatic Stress Disorder Screen (PC-PTSD)
The PC-PTSD is a 4-item"yes" or "no" screen designed for use in medical settings and is the current screening instrument used in the VA system to screen for PTSD. This is considered a psychometrically sound screen for determining the presence and absence of PTSD in the VA setting and has also been used in the civilian primary care population. With a cut-off score of 3, the PC-PTSD has shown 85% diagnostic efficiency, 78% sensitivity, and 87% specificity.
Time frame: Change in score Assessed at Baseline, 2 weeks and 4 weeks.
Generalized Anxiety Disorder (GAD7)
The GAD7 is a 7-item questionnaire that measures severity of anxiety. Response options are "not at all," "several days," "more than half the days," and "nearly every day," scored as 0, 1, 2, and 3, respectively. Therefore, GAD-7 scores range from 0 to 21, with scores of 5, 10, and 15 representing mild, moderate, and severe anxiety symptom levels, respectively
Time frame: Change in score Assessed at Baseline, 2 weeks and 4 weeks.
Demographics Questionnaire
Participants will be asked to provide standard demographic information (i.e., age, gender, race/ethnicity, level of education, etc.). Participants will also be asked about hearing and visual impairment as well as any history of motion sickness.
Time frame: Assessed at Baseline
Alcohol Use Disorder Identification Test-Consumption (AUDIT-C)
Alcohol Use Disorder Identification Test-Consumption (AUDIT-C) is a 3-item alcohol screen that can identify problem alcohol use. The AUDIT-C is scored o a scale of 0-12, each question has 5 answer choices with "a" being 0 points and "e" being 4 points.
Time frame: Assessed at Baseline, 2 weeks and 4 weeks.
Attitudes Toward the Experience Survey
The Attitudes Toward the Experience Survey is an 8-item NRS that will be used to measure the participant's attitude toward the VR experience. Participants rate the degree to which they agree with the statements on a 1-10 scale, with 0 being "strongly disagree" and 10 being "strongly agree."
Time frame: Assessed at 4 weeks
This platform is for informational purposes only and does not constitute medical advice. Always consult a qualified healthcare professional.