Radiation exposure to patients from CT for CAC scoring has steadily decreased in recent years. This is mainly achieved through lowering tube currents alongside with the introduction of iterative reconstruction algorithms which allow compensating for increased image noise. However, the greatest radiation dose reduction can be obtained by reducing peak tube voltage. Yet lowering peak tube voltage remains challenging because tissue attenuation is closely related to photon energy, thus rendering the established thresholds for calculating CAC scores (i.e. Agatston scores) incomparable if peak tube voltages other than the standard 120 kilovolt peak (kVp) are applied. The investigators have developed novel tube-adapted thresholds for CAC scoring by CT at 80 kVp and 70-kVp tube voltage and have shown that these novel thresholds are valid, yielding results closely comparable to the standard 120-kVp protocol. The present study aims to optimize application of such low-dose scans in a general population through assessment of the impact of physiological patient parameters on image parameters such as image noise which per se may impact the accuracy and feasibility of ultra-low-dose CAC scoring with reduced tube voltage. Furthermore, the prognostic performance of such low-dose CAC scoring will be elucidated.
Study Type
INTERVENTIONAL
Allocation
NA
Purpose
DIAGNOSTIC
Masking
NONE
Enrollment
301
All patients undergo two non-contrast enhanced CT scans with standard dose (i.e. 120 kVp), one with 80 kVp and one with 70 kVp.
Department of Nuclear Medicine, University Hospital Zurich
Zurich, Switzerland
Impact of BMI on CAC scores derived from low-dose versus standard-dose CT
Assessment of deviation of CAC scores derived from low-dose CT versus standard-dose CT (i.e. standard of reference) by calculating bias and Bland-Altmann limits of agreement as well as intraclass correlation in different subgroups of patients, stratified by body mass index.
Time frame: 2 years
Prognostic value of CAC scores derived from CT scans with varying tube voltages
Assessment of sensitivity and specificity CAC scores derived from low-dose CT versus standard-dose CT (i.e. standard of reference) to predict future cardiovascular events (i.e. myocardial infarction, revascularisation, death) over a short to mid-term follow-up period (i.e. 2 years).
Time frame: 2 years