Background: Patient education is one of the pillars of asthma treatment according to GINA guidelines. It has considered essential for adherence to treatment and for correct technique of inhaled devices.
Objective: analyze clinical, functional and inflammatory features of adult patients with partly controlled and uncontrolled asthma, before and after an educational intervention. Methods: 58 adult asthmatic patients (18-70 years old) were randomized into two groups: intervention group (IG) (n=38) or control group (CG) (n=26). IG patients were submitted to three 30-minutes intervention of a shortterm educational program delivered by a nurse in 3 visits with a one-month interval. CG group did not receive educational intervention. All patients were submitted to a spirometry, induced sputum collection, nitric oxide measure, collecting exhaled condensed (cytokine analysis) air and it's ph measure, Asthma Control Test (ACT), Asthma Control Questionnaire (ACQ), Asthma Quality Life Questionnaire (AQLQ), Beck Depression Inventory (BDI), and answered a symptoms diary, Statistical analysis: repeated measures (Sigma Plot Software 3.0).
Study Type
INTERVENTIONAL
Allocation
RANDOMIZED
Purpose
PREVENTION
Masking
NONE
Enrollment
64
IG patients were submitted to three 30-minutes intervention of a individualized shortterm educational program delivered by a nurse, were given explanations about general aspects of the disease, prevention methods and about the importance and correct use of inhaled corticosteroids, with an educational video showing the use of the device
All participants performed induced sputum collection
All participants performed spirometry test using a Koko spirometer. Pulmonary function was assessed by spirometry prebronchodilator, after withholding short-acting beta-agonists for ≥ 6 hours and long-acting beta-agonist for ≥ 24hours. Forced expiratory volume in one second (FEV1) % predicted was used as a proxy variable for overall lung function.
Induced sputum samples to assess airway inflammation
Induced sputum samples were collected in 3 visits with a one-month interval to assess the degree of airway inflammation. Markers of inflammation included eosinophils, neutrophils, macrophages, lymphocytes and total cell counts, as well as cytokines in the sputum supernatant. In the processing performed the subjects received up to three nebulizations with 3% hypertonic saline, the aerosol was generated by an ultrasonic nebulizer (Ultraneb 99; DeVilbiss, Somerset, PA) each challenge was monitored with peak flow before, after and between nebulizations.
Time frame: One day
Pulmonary function by spirometry
Pulmonary function was assessed by spirometry pre and after bronchodilator (Salbutamol, short action beta-agonist), according to ATS guidelines, in 3 visits with a one-month interval after withholding short-acting beta-agonists for ≥ 6 hours and long-acting betaagonist for ≥ 24hours. Forced expiratory volume in one second (FEV1) % predicted was used as a proxy variable for overall lung function
Time frame: One day
Asthma control by Asthma Control Test (ACT)
Asthma Control Test (ACT) was used to assess clinical control of asthma in the last month; is a questionnaire composed of five questions (score varying from 5 to 25 points) assessing asthma in relation to physical activity limitation, nocturnal and diurnal symptoms, shortness of breath and use of rescue medication. The higher the overall score, the greater the asthma control, and a 3-point difference in the mean ACT score is considered a clinically relevant change.
Time frame: One day
Depression symptoms by Beck Depression Inventory II (BDI II)
To evaluate the symptoms of depression reported in the last 30 days, BDI II was used, a questionnaire composed of 21 items with scores ranging from 0 to 63 points, the higher the score the worse the severity of the symptoms
Time frame: One day
Asthma quality of life by Asthma Quality of Life Questionnaire (AQLQ)
This platform is for informational purposes only and does not constitute medical advice. Always consult a qualified healthcare professional.
All participants performed nitric oxide measure in three Mylar bags and measure was performed in a NOA280 Sievers equipment. For collection the patients blew in the balloons through a sterile nozzle in the equipment collector without prejudice or damage to the patient.
All participants answered standardized questionnaires about asthma symptoms and depression: Asthma Control Test (ACT), Asthma Control Questionnaire (ACQ), Asthma Quality Life Questionnaire (AQLQ), Beck Depression Inventory (BDI)
All participants were instructed to note in the morning and evening before the use of routine inhaled corticosteroids, asthma symptoms (coughing, wheezing, shortness of breath, use of emergency inhaled corticosteroids) and three measures of peak expiratory flow (individual, provided to patients) and to return this completed diary at each study visit
All participants registered three peak flow measures in the symptoms diary by morning and night before the use of routine inhaled corticosteroids. Peak flow was measured by the electronic peak flow meter (Mini-Wright).
Exhaled breath condensate was collect during 15 to 20 minutes in a Turbo DECCS equipment (Medivac SRL, Italy) in a sterile buccal of the own apparatus with the aid of a nasal clip with the participant breathing normally without any effort or damage.
Asthma quality of life was assessed using the AQLQ, which has four domains: activity limitations, symptoms, emotional function and environmental stimuli. A higher AQLQ score indicates a better quality of life.
Time frame: One day
Fractional exhaled nitric oxide (FeNO)
FeNO was collected also to assess airway inflammation in acoordance with the ATS recommendations; all measurements were determinad by chemiluminscence (Sievers 280). This analysis procedure was performed by a blinded investigator. The patients were advised to blow into a Mylar bag, with a breath pressure of 12 cmH20, monitored by the pressure gauge, reaching a flow rate of 200 mL/s.
Time frame: One day
Exhaled breath condensate (EBC)
A Turbo DECCS® condenser (Medivac SRL, Italy) (29) was used which was cooled to -20øC for at least thirty minutes prior to use. The subjects were instructed to perform oral breathing using the mouthpiece of the equipment and with the aid of a nasal clip. The EBC (exhaled breath condensate) was collected for 15 to 20 minutes in tidal volume for pH analysis and cytokine dosing.
Time frame: One day