Monocentric cohort study, prospective, evaluating the variability of cardiac output measurement by resting and stress impedancemetry as a prognostic factor for Pulmonary Hypertension
Cardiac impedancemetry is a technique that allows an electrical representation of cardiac flows. To do this, 6 electrodes are applied to the thorax and a low intensity and high frequency electrical current is transmitted. The impedance is recorded and the variations of the impedance represent the changes in intra-thoracic volume and thus the volume of systolic ejection. This measurement can be done at rest but also during exercise during the walking test. A test of the NO / CO coupled transfer measurement is also performed. The devices that will be used in this project are the Physio-Flow® system and Masterscreen NO / CO coupled transfer measurement device
Study Type
INTERVENTIONAL
Allocation
NA
Purpose
PREVENTION
Masking
NONE
Enrollment
59
The cardiac output is measured by impedance measurement at rest and during the walking test.
CHU TOULOUSE hospital larrey
Toulouse, Midi-Pyrennée, France
Measure of cardiac flow variation at 0 month by impedancemetry
The variation of cardiac flow is measured by impedancemetry at rest
Time frame: 0 month
Measure of cardiac flow variation at 6 month by impedancemetry
The variation of cardiac flow is measured by impedancemetry at rest
Time frame: 6 month
Measure of cardiac flow variation during walking test
The variation of cardiac flow is measured by impedancemetry during walking test
Time frame: 0 month
Measure of cardiac flow variation during walking test at 6 month
The variation of cardiac flow is measured by impedancemetry during walking test
Time frame: 6 month
Correlation between measurement of capillary blood volume and measurement of cardiac flow
Evaluate the correlation between measurement of capillary blood volume and measurement of cardiac flow by impedancemetry
Time frame: 0 month
Correlation between measurement of capillary blood volume and measurement of cardiac flow
Evaluate the correlation between measurement of capillary blood volume and measurement of cardiac flow by impedancemetry
Time frame: 6 month
Occurrence of an undesirable event
Collection of undesirable event like : - Deaths (all causes combined), Hospitalization for aggravation of PAH, Progression of the disease or decrease, Unsatisfactory long-term clinical response